Download full-text PDF

Source

Publication Analysis

Top Keywords

case devices
4
devices disclosure
4
disclosure subjects
4
subjects phase
4
phase "post-marketing"
4
case
1
disclosure
1
subjects
1
phase
1
"post-marketing"
1

Similar Publications

Intraluminal prosthetic graft thrombus (IPT) has been described in case of endovascular aortic pathology repair. This study aimed to assess hemodynamic indicators associated with various anatomical morphologies following endovascular aortic repair (EVAR), aiming to offer further references for the choice of clinical therapy. Six model models (normal, iliac compression, aortic compression, aortoiliac compression, iliac distortion, and long-leg stent) were established based on common anatomical morphologies following EVAR.

View Article and Find Full Text PDF

Importance of individualized treatment: Subconjunctival device in silicone oil-induced glaucoma.

Arch Soc Esp Oftalmol (Engl Ed)

December 2024

Departamento de Oftalmología, Hospital Universitario Virgen de la Macarena, Sevilla, Spain; Miembros de la «Red de Enfermedades Inflamatorias, Enfermedades Inflamatorias Oculares, Enfermedades Inflamatorias No Infecciosas de la Superficie Ocular, Instituto de Salud Carlos III (RICORS). FISS-21-RD21/0002/0011»; Área de Oftalmología, Departamento de Cirugía, Universidad de Sevilla, Sevilla, Spain.

Although silicone oil is used as an intraocular buffer in vitreoretinal surgical procedures, its use can cause complications, including glaucoma. This study highlights the importance of individualized approaches for the management of silicone oil-induced glaucoma. A 62-year-old man with a past medical history of retinal detachment and multiple ocular surgical procedurespresented with uncontrolled ocular pressure peaks after retinal detachment surgery using silicone oil as a buffer, which did not resolve after removal of the buffer.

View Article and Find Full Text PDF

Minimizing for Maximum Benefit: An Illustrative Case-Series of Atrial Only Leadless Pacing.

Pacing Clin Electrophysiol

December 2024

Division of Cardiology, Department of Medicine, Weill Cornell Medicine, New York Presbyterian Hospital, New York, USA.

Leadless pacing technology now includesdedicated atrial helix-fixation leadless pacemakers (LPs), expanding theapplication of leadless devices for patients with sinus node dysfunction andatrioventricular block during sinus rhythm. This first reportedcase-series of atrial LPs describes and discusses the potential use-casescenarios of recently approved helix-fixation atrial LPs. The article highlights important concepts regarding their use, including implantationtechniques, programming, battery conservation, and the low rate of progressionof AV block in patients implanted with AAI(R) pacemakers.

View Article and Find Full Text PDF

Reel's syndrome (RS) is an unusual cause of pacemaker lead dislodgement. We present the case of a 59-year-old female patient with Down syndrome (DS) implanted with a dual-chamber endovascular pacemaker due to symptomatic sinus node disfunction, reporting several syncopal episodes in last days and showing abnormal electrical parameters at the 2-months follow-up due to RS. The malfunctioning device was removed and an endocardial leadless pacing system was implanted.

View Article and Find Full Text PDF

Background: Parkinson's disease (PD) is a neurodegenerative disorder that affects millions of people worldwide. Mobile technologies enable Parkinson's patients to improve their quality of life, manage symptoms, and enhance overall well-being through various applications (apps). There is no integrated list of specific capabilities available to cater to the unique needs of Parkinson's patient-focused mobile apps.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!