Contrast between blood and myocardium in standard turbo gradient echo MR techniques (TFE) used routinely in clinical practice is mainly caused by unsaturated inflowing blood. Steady-state free precession (SSFP) has excellent contrast even in the absence of inflow effects. In 45 subjects cardiac cine loops in two long axis projections were acquired using TFE and compared with SSFP. A visual score (range 0 worst - 3 best) was assigned for endocardial border delineation for six myocardial segments in two long axis views. Endocardial border delineation score for TFE was 1.3 +/- 0.3 per segment and 2.4 +/- 0.3 for SSFP (P < 0.0001). Signal intensity blood/signal intensity myocardium was 1.5 +/- 0.4 at enddiastole and 1.4 +/- 0.3 at systole for TFE and 3.5 +/- 1.1 and 3.2 +/- 1.3 for SSFP, respectively (P < 0.0001). SSFP increases contrast between blood and myocardium more than twofold, resulting in an improved endocardial border definition. This may reduce variability for the determination of cardiac volumes and ejection fraction.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jmri.1195DOI Listing

Publication Analysis

Top Keywords

endocardial border
16
border delineation
12
steady-state free
8
free precession
8
precession ssfp
8
contrast blood
8
blood myocardium
8
long axis
8
tfe +/-
8
+/- ssfp
8

Similar Publications

Background: Percutaneous extracorporeal membrane oxygenation (ECMO) is administered to pediatric patients with cardiogenic shock or cardiac arrest. The traditional method uses focal echocardiography to complete the left ventricular measurement. However, echocardiographic determination of the ejection fraction (EF) by manual tracing of the endocardial borders is time consuming and operator dependent.

View Article and Find Full Text PDF

The role of artificial intelligence in standardizing global longitudinal strain measurements in echocardiography.

Eur Heart J Imaging Methods Pract

October 2024

Department for Internal Medicine and Cardiology, Herzzentrum Dresden, Faculty of Medicine and University Hospital Carl Gustav Carus, TUD Dresden University of Technology, Fetscherstr. 76, 01307 Dresden, Germany.

Aims: To evaluate the accuracy and feasibility of artificial intelligence (AI) in left ventricular global longitudinal strain (GLS) analysis as compared to conventional (Manual) and semi-automated (SemiAuto) method in echocardiography (Echo).

Methods And Results: GLS validation was performed on 550 standard Echo exams by expert cardiologists. The performance of a beginner cardiologist without experience of GLS analysis was assessed on a subset of 90 exams.

View Article and Find Full Text PDF

Non-invasive pressure-volume loops show high arterial elastance in children with repaired tetralogy of Fallot.

Scand Cardiovasc J

December 2024

Clinical Physiology, Department of Clinical Sciences Lund, Skåne University Hospital, Lund University, Lund, Sweden.

Article Synopsis
  • Children with repaired tetralogy of Fallot (rToF) exhibit distinct changes in left ventricular (LV) function and right ventricular (RV) size compared to healthy peers, including larger RV volumes and smaller LV volumes.
  • The study measured haemodynamic variables using non-invasive techniques, revealing higher arterial elastance and heart rates in children with rToF, suggesting a compensatory response to impaired LV filling.
  • Further research is needed to understand the implications for cardiovascular health and the potential increased risk for adverse events in these patients.
View Article and Find Full Text PDF

Echocardiographic image quality deteriorates with the severity of cardiogenic shock.

Egypt Heart J

August 2024

William Harvey Research Institute, Barts and the London School of Medicine and Dentistry, Queen Mary University of London, Charterhouse Square, London, UK.

Background: Transthoracic echocardiography (TTE) is the primary tool for assessing left ventricular (LV) function in cardiogenic shock (CS). However, inadequate image quality often hinders it. In this retrospective study, we investigated factors associated with LV image quality in patients admitted to the intensive care unit (ICU) with ischemic CS.

View Article and Find Full Text PDF

Introduction: Speckle tracking echocardiography is a non-Doppler modality allowing the semiautomated evaluation of the fetal cardiac function by tracking the speckles of the endocardial borders. Little evidence is available on the evaluation and comparison of different software for the functional assessment of the fetal heart by means of speckle tracking echocardiography. The aim of this study was to evaluate the reproducibility and agreement of two different proprietary speckle tracking software for the prenatal semiautomated assessment of the fetal cardiac function.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!