Multiplexed fluorescent bead-based immunoassays for quantitation of human cytokines in serum and culture supernatants.

Cytometry

Scientific Resources Program, National Center for Infectious Diseases, Centers for Disease Control and Prevention, Atlanta, Georgia 30333, USA.

Published: September 2001

Background: An increasing volume of data suggests a relationship between cytokine levels in human body fluids and disease pathogenesis. Traditionally, many individual assays would be performed to measure the large number of known cytokines and determine their associations with disease. A new technique for the simultaneous measurement of multiple cytokines in cell culture supernatants by fluorescent microsphere-based flow cytometry was adapted to human sera.

Methods: Multiplexed sandwich immunoassays for eight cytokines were developed by coupling cytokine-specific capture antibodies to beads with different emission spectra. The binding of biotinylated detection antibodies bound with a streptavidin-conjugated fluorochrome was analyzed. Recovery of "spiked" cytokines, sensitivity, and variability of the assays were evaluated. In addition, the results of the bead assays were compared with the results of commercial enzyme-linked immunosorbent assays (ELISAs) that used the same antibody pairs.

Results: Correlations of the bead assays and the ELISAs were 0.974 (n = 18) for supernatant samples and 0.859 (n = 28) for serum samples. High, false-positive values observed with some sera, assumed to be produced by heterophilic antibodies, were reduced by preincubation with a cocktail of animal sera.

Conclusions: Fluorescent bead-based immunoassays can be used to quantitate multiple cytokines in human sera and contribute to an understanding of the role of cytokines in disease processes. This methodology is applicable to many combinations of purified analytes and high-affinity antibodies. Published 2001 Wiley-Liss, Inc.

Download full-text PDF

Source
http://dx.doi.org/10.1002/1097-0320(20010901)45:1<27::aid-cyto1141>3.0.co;2-iDOI Listing

Publication Analysis

Top Keywords

fluorescent bead-based
8
bead-based immunoassays
8
culture supernatants
8
multiple cytokines
8
bead assays
8
assays elisas
8
cytokines
7
assays
5
multiplexed fluorescent
4
immunoassays quantitation
4

Similar Publications

Introduction: This study investigated the efficacy of pooled human immune globulins (Flebogamma DIF) to combat the formation of neutrophil extracellular traps (NETs) and NETosis, along with neutrophil adhesion to corneal epithelial cells in response to dry eye disease relevant stimuli.

Methods: Human neutrophils were isolated by bead-based immunomagnetic depletion of non-target cells from human whole blood. NETosis was induced using phorbol 12-myristate 13-acetate (PMA) or anti-citrullinated histone 4 R3 antibody (H4R3 ACPA).

View Article and Find Full Text PDF

A magnetic bead-based dual-aptamer sandwich assay for quantitative detection of ciprofloxacin using CRISPR/Cas12a.

Mol Cell Probes

December 2024

School of Basic Medical Sciences, Zhengzhou University, Zhengzhou, Henan, 450001, PR China; School of Basic Medical Sciences Innovation and Entrepreneurship Base for College Students, Zhengzhou University, Zhengzhou, Henan, 450001, PR China. Electronic address:

Ciprofloxacin (CIP) is a broad-spectrum fluoroquinolone antibiotic, and its excessive residues in food and water sources pose potential risks to human health. Therefore, there is a need for a rapid and convenient method for its accurate quantification. The clustered regularly interspaced short palindromic repeat (CRISPR)/Cas12a system has gained extensive application in signal detection and amplification due to the trans-cleavage activity of Cas12a.

View Article and Find Full Text PDF

DNA-modifying enzymes are crucial in biological processes and have significant clinical implications. Traditional quantification methods often overlook enzymatic activity, the true determinants of enzymes' functions. We present hydrogel Bead-based Isothermal Detection (BEAD-ID), utilizing uniform hydrogel bead-based microreactors to evaluate DNA-modifying enzyme activity on-bead.

View Article and Find Full Text PDF

Canine mammary tumor (CMT) is a prevalent and destructive disease often diagnosed at an advanced stage, leading to poor outcomes. Currently, there is a lack of effective biomarkers for early detection and prognostic prediction of CMT. To improve CMT detection, we established a multiplexed immunoassay using a fluorescence bead-based suspension array system to measure serum levels of autoantibodies against four CMT-associated proteins (AGR2, HAPLN1, IGFBP5, and TYMS) in CMT patients.

View Article and Find Full Text PDF

Vaccination against is advised for transplant recipients to reduce morbidity and mortality associated with invasive pneumococcal disease. However, data on alloantibodies after sequential vaccination (with a pneumococcal conjugate vaccine followed by a polysaccharide vaccine) are still lacking. In the current study, we determined HLA class I and II and major histocompatibility class I-related chain A (MICA) antibodies in 41 clinically stable kidney transplant recipients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!