The objective of this study was to validate a real-time 3-dimensional echocardiography (3DE) technique for the determination of left ventricular (LV) volume and ejection fraction (EF). In 10 mongrel dogs, an electromagnetic flow (EMF) probe was placed on the aorta, and the thorax was closed. Transthoracic imaging was performed during multiple hemodynamic conditions (n = 58) with simultaneous measurement of stroke volume (SV) with the use of EMF. From the volumetric data set, LV volumes were manually traced off-line by 2 independent observers with an apical rotation method (6 planes) and a conventional method (biplane) in a subset of conditions. This tracing technique was also evaluated in 18 human subjects in whom the calculated EF values were compared with values derived by multigated radionuclide angiography (MUGA). Excellent correlation and close limits of agreement were noted between SV measured by 3DE and EMF (r = 0.93) in dogs. In comparison with EMF-derived SV, 3DE provided better correlation than the biplane method (r = 0.93 versus r = 0.61). Interobserver and intraobserver variabilities were comparable (r = 0.94 and r = 0.94, respectively). In a comparison of MUGA-derived EF values and those obtained by 3DE in human subjects, 3DE provided better correlation than the biplane method (r = 0.94 versus r = 0.85). Real-time 3DE accurately measures left ventricular volumes transthoracically over a wide range of hemodynamic conditions in dogs and accurately determines EF in humans.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1067/mje.2001.115770 | DOI Listing |
Ultrasound J
January 2025
Health Sciences North Research Institute, Sudbury, ON, Canada.
The duration of mechanical systole-also termed the flow time (FT) or left ventricular ejection time (LVET)-is measured by Doppler ultrasound and increasingly used as a stroke volume (SV) surrogate to guide patient care. Nevertheless, confusion exists as to the determinants of FT and a critical evaluation of this measure is needed. Using Doppler ultrasound of the left ventricular outflow tract velocity time integral (LVOT VTI) as well as strain and strain rate echocardiography as grounding principles, this brief commentary offers a model for the independent influences of FT.
View Article and Find Full Text PDFInt J Legal Med
January 2025
Institute for Legal Medicine, Faculty of Medicine, Saarland University, Campus Homburg, Building 49.1, Kirrberger Straße 100, 66421, Homburg/Saar, Germany.
Aortic regurgitation is a common valve disease and can be caused by delineated findings such as fenestrations or hardly discernible alterations of the aortic root geometry. Therefore, aortic regurgitation can be a challenging diagnosis during an autopsy. Cardiac surgeons, however, are confronted with comparable problems during surgery and have developed a refined knowledge of the anatomy of the aortic root including its geometry.
View Article and Find Full Text PDFEur Heart J Cardiovasc Imaging
January 2025
Department of Cardiovascular Medicine, Gunma University Graduate School of Medicine, Maebashi, Gunma, Japan.
Aims: Left ventricular (LV) diastolic dysfunction and heart failure with preserved ejection fraction (HFpEF) are common cardiac complications of patients with systemic sclerosis (SSc). Exercise stress echocardiography is often used in symptomatic patients with SSc to detect abnormal increases in pulmonary pressures during exercise, but the pathophysiologic and prognostic significance of exercise stress echocardiography to assess the presence of HFpEF in these patients is unclear.
Methods And Results: Patients with SSc (n=140) underwent ergometry exercise stress echocardiography with simultaneous expired gas analysis.
Artif Organs
January 2025
Division of Cardiology, Department of Medicine, Columbia University College of Physicians and Surgeons and NewYork-Presbyterian Hospital, New York, New York, USA.
Background: GLP-1 RAs improve cardiometabolic outcomes in obese, diabetic, and heart failure patients. Data on the safety and efficacy of GLP-1 RA in advanced heart failure with durable LVAD is limited.
Objectives: To assess the safety and efficacy of GLP-1 RA in durable LVAD patients.
J Vet Intern Med
January 2025
Boehringer Ingelheim Pharma GmbH & Co., Ingelheim, Germany.
Background: Myxomatous mitral valve disease (MMVD) is frequently diagnosed in small breed dogs. Pimobendan oral solution has been developed to improve dosing accuracy in small and toy breed dogs.
Hypothesis/objectives: Demonstrate bioequivalence of pimobendan oral solution with pimobendan chewable tablets using a pharmacokinetic and a pharmacodynamic study in healthy purpose bred dogs.