The objective of this study was to validate a real-time 3-dimensional echocardiography (3DE) technique for the determination of left ventricular (LV) volume and ejection fraction (EF). In 10 mongrel dogs, an electromagnetic flow (EMF) probe was placed on the aorta, and the thorax was closed. Transthoracic imaging was performed during multiple hemodynamic conditions (n = 58) with simultaneous measurement of stroke volume (SV) with the use of EMF. From the volumetric data set, LV volumes were manually traced off-line by 2 independent observers with an apical rotation method (6 planes) and a conventional method (biplane) in a subset of conditions. This tracing technique was also evaluated in 18 human subjects in whom the calculated EF values were compared with values derived by multigated radionuclide angiography (MUGA). Excellent correlation and close limits of agreement were noted between SV measured by 3DE and EMF (r = 0.93) in dogs. In comparison with EMF-derived SV, 3DE provided better correlation than the biplane method (r = 0.93 versus r = 0.61). Interobserver and intraobserver variabilities were comparable (r = 0.94 and r = 0.94, respectively). In a comparison of MUGA-derived EF values and those obtained by 3DE in human subjects, 3DE provided better correlation than the biplane method (r = 0.94 versus r = 0.85). Real-time 3DE accurately measures left ventricular volumes transthoracically over a wide range of hemodynamic conditions in dogs and accurately determines EF in humans.

Download full-text PDF

Source
http://dx.doi.org/10.1067/mje.2001.115770DOI Listing

Publication Analysis

Top Keywords

left ventricular
12
real-time 3-dimensional
8
3-dimensional echocardiography
8
determination left
8
hemodynamic conditions
8
human subjects
8
3de provided
8
provided better
8
better correlation
8
correlation biplane
8

Similar Publications

The duration of mechanical systole-also termed the flow time (FT) or left ventricular ejection time (LVET)-is measured by Doppler ultrasound and increasingly used as a stroke volume (SV) surrogate to guide patient care. Nevertheless, confusion exists as to the determinants of FT and a critical evaluation of this measure is needed. Using Doppler ultrasound of the left ventricular outflow tract velocity time integral (LVOT VTI) as well as strain and strain rate echocardiography as grounding principles, this brief commentary offers a model for the independent influences of FT.

View Article and Find Full Text PDF

Left ventricular rigor mortis interferes with postmortem aortic root geometry.

Int J Legal Med

January 2025

Institute for Legal Medicine, Faculty of Medicine, Saarland University, Campus Homburg, Building 49.1, Kirrberger Straße 100, 66421, Homburg/Saar, Germany.

Aortic regurgitation is a common valve disease and can be caused by delineated findings such as fenestrations or hardly discernible alterations of the aortic root geometry. Therefore, aortic regurgitation can be a challenging diagnosis during an autopsy. Cardiac surgeons, however, are confronted with comparable problems during surgery and have developed a refined knowledge of the anatomy of the aortic root including its geometry.

View Article and Find Full Text PDF

Aims: Left ventricular (LV) diastolic dysfunction and heart failure with preserved ejection fraction (HFpEF) are common cardiac complications of patients with systemic sclerosis (SSc). Exercise stress echocardiography is often used in symptomatic patients with SSc to detect abnormal increases in pulmonary pressures during exercise, but the pathophysiologic and prognostic significance of exercise stress echocardiography to assess the presence of HFpEF in these patients is unclear.

Methods And Results: Patients with SSc (n=140) underwent ergometry exercise stress echocardiography with simultaneous expired gas analysis.

View Article and Find Full Text PDF

Background: GLP-1 RAs improve cardiometabolic outcomes in obese, diabetic, and heart failure patients. Data on the safety and efficacy of GLP-1 RA in advanced heart failure with durable LVAD is limited.

Objectives: To assess the safety and efficacy of GLP-1 RA in durable LVAD patients.

View Article and Find Full Text PDF

Pimobendan oral solution is bioequivalent to pimobendan chewable tablets in beagle dogs.

J Vet Intern Med

January 2025

Boehringer Ingelheim Pharma GmbH & Co., Ingelheim, Germany.

Background: Myxomatous mitral valve disease (MMVD) is frequently diagnosed in small breed dogs. Pimobendan oral solution has been developed to improve dosing accuracy in small and toy breed dogs.

Hypothesis/objectives: Demonstrate bioequivalence of pimobendan oral solution with pimobendan chewable tablets using a pharmacokinetic and a pharmacodynamic study in healthy purpose bred dogs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!