Vascular compromise associated with supracondylar fractures in children.

Saudi Med J

Division of Vascular Surgery, Department of Surgery, College of Medicine, King Khalid University Hospital, Riyadh, Kingdom of Saudi Arabia.

Published: September 2001

Objective: Our aim was to study the significance of persistently absent radial pulse, with monophasic doppler flow after close reduction percutaneous pinning of displaced supracondylar fracture of humerus, and the need of early exploration of brachial artery in such cases.

Methods: Between July 1992 and 1999, 86 children with Grade III supracondylar fracture of humerus were treated at King Khalid University Hospital, Riyadh, Kingdom of Saudi Arabia The history, physical examination, vascular status of limb before and after close reduction percutaneous pinning of fracture were recorded. All children having persistently absent radial pulse and monophasic flow doppler signals after close reduction percutaneous pinning under went exploration of brachial artery.

Results: Of the 86 children with Grade III supracondylar fracture of humerus, 6 had persistently absent radial pulse with monophasic flow doppler signals after close reduction percutaneous pinning. Five children had one warm pink well perfused hand and one cold pale poorly perfused hand. All 6 under went exploration of brachial artery and were found to have entrapped artery at the fracture site. There was an immediate return of radial pulse with triphasic Doppler flow on release of brachial artery.

Conclusion: Persistently absent radial pulse with objectivity, obtained by doppler ultrasound in the form of absent or monophasic flow in radial artery, is a reliable indicator of vascular compromise. Surgical exploration of brachial artery by a competent surgeon is to be carried out to avoid early and late complication, of pulseless limb in children with displaced supracondylar fracture of humerus.

Download full-text PDF

Source

Publication Analysis

Top Keywords

radial pulse
20
persistently absent
16
absent radial
16
close reduction
16
reduction percutaneous
16
percutaneous pinning
16
supracondylar fracture
16
fracture humerus
16
exploration brachial
16
pulse monophasic
12

Similar Publications

We propose and demonstrate an ultra-wide tunable mode-locked all-fiber laser based on nonlinear amplifying loop mirror (NALM) with the output of cylindrical vector beams (CVBs). The tuning range covers from 1029 nm to 1098 nm through the intracavity nonlinear polarization evolution (NPE) filter effect. The switchable CVBs between radially and azimuthally polarized beams with mode purity above 90% are generated by incorporating a broadband few-mode long-period fiber grating (LPFG).

View Article and Find Full Text PDF

In this work, we introduce spatial and chemical saturation options for artefact reduction in magnetic resonance fingerprinting (MRF) and assess their impact on T and T mapping accuracy. An existing radial MRF pulse sequence was modified to enable spatial and chemical saturation. Phantom experiments were performed to demonstrate flow artefact reduction and evaluate the accuracy of the T and T maps.

View Article and Find Full Text PDF

Objectives: Brachial artery injury due to displaced supracondylar fracture (SC) of the humerus in children may present with pink pulseless hand (PPH), denoting a well perfused hand without radial pulse, or acute hand ischemia. Some reports state that brachial artery reconstruction is not necessary in children with persisting PPH, but the reports on long-term consequences such as intermittent claudications, growth retardation and ischemic contracture in children with pulseless hand are scarce and often misinterpreted. The objective of our analysis was to assess the long-term outcomes of children with brachial artery injury associated with SC fracture.

View Article and Find Full Text PDF

The purpose of this study was to clarify sex differences in the inhibition of sympathetic vasomotor outflow which is caused by the loading of cardiopulmonary baroreceptors. Ten young males and ten age-matched females participated. The participants underwent a passive leg raising (PLR) test wherein they were positioned supine (baseline, 0º), and their lower limbs were lifted passively at 10º, 20º, 30º, and 40º.

View Article and Find Full Text PDF

Ultra-high-resolution brain MRI at 0.55T: bSTAR and its application to magnetization transfer ratio imaging.

Z Med Phys

January 2025

Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland; Department of Radiology, Division of Radiological Physics, University Hospital Basel, Basel, Switzerland.

Purpose: This study aims to evaluate the feasibility of structural sub-millimeter isotropic brain MRI at 0.55 T using a 3D half-radial dual-echo balanced steady-state free precession sequence, termed bSTAR and to assess its potential for high-resolution magnetization transfer imaging.

Methods: Phantom and in-vivo imaging of three healthy volunteers was performed on a low-field 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!