Current status of personal dosimetry in industry, research and medicine in Lithuania.

Radiat Prot Dosimetry

Ministry of Health, Radiation Protection Centre, Kalvariju 153, Vilnius LT-2042, Lithuania.

Published: March 2002

The personal dosimetry service of the Radiation Protection Centre performs individual monitoring for all the industrial, medical and research radiation workers. The RADOS and DTU TLD systems are used for monitoring of doses. The DTU TLD system is used for measurements of doses to extremities and for measurements of public external exposure. Finger ring TLDs are used in therapy which uses radiopharmaceuticals. The RADOS system is also used for evaluation of patients' doses in selected hospitals. The dosimetry service recently provided individual monitoring of approximately 3000 workers. The average occupational dose was about 1.06 mSv for medical workers and 3.2 mSv for industrial radiography workers in 1999. Detailed analysis of doses received by different categories of workers is performed. A system for the urgent review of work conditions in the case of increased dose has been set up.

Download full-text PDF

Source
http://dx.doi.org/10.1093/oxfordjournals.rpd.a006607DOI Listing

Publication Analysis

Top Keywords

personal dosimetry
8
dosimetry service
8
individual monitoring
8
dtu tld
8
workers
5
current status
4
status personal
4
dosimetry industry
4
industry medicine
4
medicine lithuania
4

Similar Publications

Background: This study aimed to quantify radiation doses during navigational bronchoscopy procedures, comparing them with reported cohorts and evaluating the LungVision (Body Vision Medical Inc.) system's efficacy in dose reduction.

Methods: This retrospective observational study included 52 consecutive navigational bronchoscopy cases, categorized into 4 imaging groups based on the C-arm: Cios Spin (Siemens Healthineers), or OEC 9900 (GE HealthCare); and the 3D tomographic imaging algorithm: Cios Spin's onboard imaging, or LungVision's AI-driven imaging.

View Article and Find Full Text PDF

Eye lens dosimetry: does the direction of rotation (vertical or horizontal) play a role in type testing?

J Radiol Prot

January 2025

Radiation Protection Dosimetry (6.3), Physikalisch-Technische Bundesanstalt, Braunschweig, NDS, GERMANY.

With the International Commission on Radiological Protection (ICRP) lowering the annual dose limit for the eye lens to 20 mSv, precise monitoring of eye lens exposure has become essential. The personal dose equivalent at a depth of 3 mm, Hp(3), is the measurement method for monitoring the dose to the lens of the eye. Traditional dosimetry methods primarily address lateral radiation exposure scenarios, where radiation approaches from the left or right, necessitating the rotation of the phantom during type testing around the vertical axis.

View Article and Find Full Text PDF

Purpose: Due to the extensive use of radiation in various fields, such as food safety, sterilizing surgical materials, and medical diagnostics, it is essential to minimize radiation exposure for both patients and healthcare professionals, even at low doses. To meet this requirement, a composite film has been developed using polyvinyl alcohol (PVA) polymer and nitro blue tetrazolium (NBT) dye to measure low radiation doses effectively.

Methods: Various concentrations of NBT dye (ranging from 0.

View Article and Find Full Text PDF

Shadow Shield Whole Body Counter (SSWBC) is used to estimate internal dose of radiation workers due to the intake of fission and activation products. The SSWBC geometry was numerically modelled in FLUKA code. The computational model was validated by comparing the experimental and simulated counting efficiencies (CEs), also known as response, using Bhabha Atomic Research Centre (BARC) reference BOttle Mannequin Absorption (BOMAB) phantom.

View Article and Find Full Text PDF

This paper explores the adaptation and application of i-TED Compton imagers for real-time dosimetry in Boron Neutron Capture Therapy (BNCT). The i-TED array, previously utilized in nuclear astrophysics experiments at CERN, is being optimized for detecting and imaging 478 keV gamma-rays, critical for accurate BNCT dosimetry. Detailed Monte Carlo simulations were used to optimize the i-TED detector configuration and enhance its performance in the challenging radiation environment typical of BNCT.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!