Objective: To generate reference ranges for bioelectrical impedance indices throughout pregnancy and to investigate whether a relationship exists between these indices and the neonatal birth weight.
Study Design: Pregnant women with a singleton gestation, gestational age lower than 12 weeks, and absence of medical diseases before pregnancy were enrolled. Patients with pregnancy complications, such as hypertensive disorders, diabetes, and antiphospholipides syndrome were excluded. Antrophometric maternal parameters and bioelectrical impedance measurements were performed during the first, second, third trimester of pregnancy, at delivery and 60 days after delivery. Height(2)/resistance (cm(2)/Omega) and height(2)/reactance (cm(2)/Omega) were utilized to estimate the total and extracellular body water amounts, respectively. Spearman rank correlations and cox proportional hazard modelling were used for statistical purposes.
Results: 169 patients completed all measurements. Total and extracellular water amounts significantly increase as pregnancy advances and return to the pre-pregnancy values within 60 days after delivery. After adjustment for gestational age at delivery, fetal sex, and smoking habits, height(2)/resistance at 25 weeks (hazard=1.04, 95% confidence interval (CI) 1.02-1.06, P<0.005), height(2)/resistance at 30 weeks (hazard=1.03, 95% CI 1.01-1.05, P<0.005), height(2)/reactance at 20 weeks (hazard=1.03,95% CI 1.01-1.05, P<0.005), and height(2)/reactance at 25 weeks (hazard=1.03, 95% CI 1.01-1.04, P<0.01) were found to be independent predictors of birth weight.
Conclusion: We have provided reference ranges for bioimpedance analysis during pregnancy, an easy, fast and non invasive method to estimate the body water composition during pregnancy. Bioelectrical impedance indices during the second trimester of pregnancy are independently related to the birth weight.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0301-2115(01)00330-x | DOI Listing |
Bioelectromagnetics
January 2025
Seibersdorf Labor GmbH, Seibersdorf, Austria.
The electrical conductivity of human tissues is a major source of uncertainty when modelling the interactions between electromagnetic fields and the human body. The aim of this study is to estimate human tissue conductivities in vivo over the low-frequency range, from 30 Hz to 1 MHz. Noninvasive impedance measurements, medical imaging, and 3D surface scanning were performed on the forearms of ten volunteer test subjects.
View Article and Find Full Text PDFBiomed Eng Online
January 2025
Department of Cardiovascular Surgery, Division of Cardiovascular Medicine, The Sixth Medical Center, Chinese PLA General Hospital, No.6 of Fucheng Road, Haidian District, Beijing, 100853, China.
Objective: This study aims to investigate the monthly variation patterns of bioelectrical impedance (BEI) along 24 meridian pathways in healthy individuals.
Methods: A cohort of 684 healthy middle-aged participants from North China was enrolled between July 1, 2017, and September 5, 2020. BEI measurements were consistently recorded along the 24 meridian pathways over the study period.
J Physiol Anthropol
January 2025
University of Wrocław, Wrocław, Poland.
Background: The oxidative handicap hypothesis posits that testosterone-dependent traits, such as muscle mass and strength, may be costly to develop due to testosterone's pro-oxidative properties, leading to increased oxidative stress. This hypothesis suggests that only individuals with superior biological conditions can afford these costs. This study examines the oxidative handicap hypothesis, exploring the relationship between muscle mass or handgrip strength and oxidative stress markers in men.
View Article and Find Full Text PDFCrit Care
January 2025
Keenan Centre for Biomedical Research, Li Ka Shing Knowledge Institute, Unity Health Toronto, Toronto, ON, Canada.
Background: In patients with acute hypoxemic respiratory failure (AHRF) under mechanical ventilation, the change in pressure slope during a low-flow insufflation indicates a global airway opening pressure (AOP) needed to reopen closed airways and may be used for titration of positive end-expiratory pressure.
Objectives: To understand 1) if airways open homogeneously inside the lungs or significant regional AOP variations exist; 2) whether the pattern of the pressure slope change during low-flow insufflation can indicate the presence of regional AOP variations.
Methods: Using electrical impedance tomography, we recorded low-flow insufflation maneuvers (< 10 L/min) starting from end-expiratory positive pressure 0-5 cmHO.
J Phys Chem Lett
January 2025
Synchrotron SOLEIL, L'Orme des Merisiers, Départementale 128, 91190 Saint-Aubin, France.
We study the influence of electrical biasing on the modification of the chemical composition and electrical performance of perovskite solar cells (PSCs) by coupling electrochemical impedance spectroscopy (EIS) and scanning transmission X-ray microscopy (STXM) techniques. EIS reveals the formation of charge accumulation at the interfaces and changes in the resistive and capacitive properties. STXM study on PSCs after applying a strong electric field for a long biasing time indicates the breakdown of methylammonium (MA) cation, promoting iodide ions to migrate and create defects at the interface.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!