A new sensitive and specific liquid chromatographic method coupled with tandem mass spectrometric detection was set up and validated for the simultaneous quantitation of vinorelbine, its main metabolite, 4-O-deacetylvinorelbine and two other minor metabolites, 20'-hydroxyvinorelbine and vinorelbine 6'-oxide. All these compounds, including vinblastine (used as internal standard) were deproteinised from blood, plasma and faeces (only diluted in urine), analysed on a cyano column and detected on a Micromass Quattro II system in the positive ion mode after ionisation, using an electrospray ion source. Under tandem mass spectrometry conditions, the specific product ions led one to accurately quantify vinorelbine and its metabolites in all biological fluids. In whole blood, linearity was assessed up to 200 ng/ml for vinorelbine and up to 50 ng/ml for the metabolites. The limit of quantitation was validated at 250 pg/ml for both vinorelbine and 4-O-deacetylvinorelbine. In the other biological media, the linearity was assessed within a same range and the limit of quantitation was adjusted according to the expected concentrations of each compound. This method was initially developed in order to identify the metabolite structures and to elucidate the metabolic pathway of vinorelbine. Thanks to its high sensitivity, this method has enabled the quantitation of vinorelbine and all its metabolites in whole blood over 168 h (i.e., 4-5 elimination half lives) whilst the previous liquid chromatographic methods allowed their measurement for a maximum of 48-72 h. Therefore, using this method has improved the reliability of the pharmacokinetic data analysis of vinorelbine.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0021-9673(01)00993-1DOI Listing

Publication Analysis

Top Keywords

tandem mass
12
vinorelbine metabolites
12
vinorelbine
9
method coupled
8
coupled tandem
8
mass spectrometric
8
spectrometric detection
8
analysis vinorelbine
8
metabolites blood
8
blood plasma
8

Similar Publications

N-acetyl-tryptophan in Acute Kidney Injury after Cardiac Surgery.

J Am Soc Nephrol

January 2025

State Key Laboratory of Natural Medicines, China Pharmaceutical University, Nanjing, 210009, China.

Background: Cardiac surgery-associated acute kidney injury is a common serious complication after cardiac surgery. Currently, there are no specific pharmacological therapies. Our understanding of its pathophysiology remains preliminary.

View Article and Find Full Text PDF

An increasing number of cannabis-related products have become available and entered the market, particularly those containing cannabidiol (CBD) and Δ-tetrahydrocannabinol (Δ-THC). Analytical methods for cannabinoids in urine have been described extensively in the literature. However, methods providing good resolution for distinguishing interferences from THC positional isomers are needed.

View Article and Find Full Text PDF

Miniaturized mass spectrometers offer significant potential for in situ analysis due to their high specificity and portability. In traditional data-dependent acquisition (DDA) mode, precursor ions for tandem analysis are selected based on the full-scan mass spectrum. However, in situ applications often require the direct analysis of complex samples without extensive sample pretreatment, making them susceptible to chemical noise that can result in false negatives.

View Article and Find Full Text PDF

Glycosylation is an important posttranslational modification in platelets, and the glycosylation pattern is critical for platelet function. To date, the exploration of the roles of various glycoforms in specific platelet functions is largely lacking. In this study, a global analysis of intact N-glycopeptides in human platelets was performed to map all the glycopeptides, glycosites and glycans of platelets.

View Article and Find Full Text PDF

Since the 1990s, the Pacific oyster has faced significant mortality, which has been associated with the detection of the Ostreid Herpesvirus type 1 (OsHV-1). Due to the complex genomic architecture and the presence of multiple genomic isomers, short-read sequencing using Illumina method struggles to accurately assemble tandem and repeat regions and to identify and characterize large structural variations in the OsHV-1 genome. Third-generation sequencing technologies, as long-read real-time nanopore sequencing from Oxford Nanopore Technologies (ONT), offer new possibilities for OsHV-1 whole-genome analysis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!