Results of the experiments on board Cosmos-2044 (Biosatellite 9) are presented. Various nuclear track detectors (NTD) (dielectric, AgCl-based, nuclear emulsions) were used to obtain the LET spectra inside and outside the satellite. The spectra from the different NTDs have proved to be in general agreement. The results of LET spectra calculations using two different models are also presented. The resultant LET distributions are used to calculate the absorbed and equivalent doses and the orbit-averaged quality factors (QF) of the cosmic rays (CR). Absorbed dose rates inside (approximately 20 g cm-2 shielding) and outside (1 g cm-2) the spacecraft, omitting electrons, were found to be 4.8 and 8.6 mrad d-1, respectively, while the corresponding equivalent doses were 8.8 and 19.7 mrem d-1. The effects of the flight parameters on the total fluence of, and on the dose from, the CR particles are analyzed. Integral dose distributions of the detected particles are also determined. The LET values which separate absorbed and equivalent doses into 50% intervals are estimated. The CR-39 dielectric NTD is shown to detect 20-30% of the absorbed dose and 60-70% of the equivalent dose in the Cosmos-2044 orbit. The influence of solar activity phase on the magnitude of CR flux is discussed.

Download full-text PDF

Source
http://dx.doi.org/10.1016/1359-0189(92)90093-bDOI Listing

Publication Analysis

Top Keywords

equivalent doses
12
board cosmos-2044
8
cosmos-2044 biosatellite
8
absorbed equivalent
8
absorbed dose
8
dose
5
cosmic ray
4
spectra
4
ray spectra
4
doses
4

Similar Publications

Sepiapterin is an exogenously synthesized new chemical entity that is structurally equivalent to endogenous sepiapterin, a biological precursor of tetrahydrobiopterin (BH), which is a cofactor for phenylalanine hydroxylase. Sepiapterin is being developed for the treatment of hyperphenylalaninemia in pediatric and adult patients with phenylketonuria (PKU). This study employed concentration-QT interval analysis to assess QT prolongation risk following sepiapterin treatment.

View Article and Find Full Text PDF

Reducing Overprescription Practices for Opioid Use Post Anterior Cervical Surgery: The Impact of a Standardized Prescription Protocol.

J Am Acad Orthop Surg

January 2025

From Davis Department of Orthopaedic Surgery, University of California, Sacramento, CA (Pina, Shahzad, Wick, Javidan, Roberto, Klineberg, and Le), and the Davis School of Medicine, University of California, Sacramento, CA (Booze, Seidu, and Shen).

Purpose: This study aimed to evaluate the impact of implementing a standardized opioid prescription protocol on prescription practices post-elective ACS surgery at a large academic institute.

Methods: A prospective cohort study with a retrospective control group was conducted following institutional review board approval. A standardized protocol was created and implemented which specified opioid prescriptions post-surgery.

View Article and Find Full Text PDF

Eye lens dosimetry: does the direction of rotation (vertical or horizontal) play a role in type testing?

J Radiol Prot

January 2025

Radiation Protection Dosimetry (6.3), Physikalisch-Technische Bundesanstalt, Braunschweig, NDS, GERMANY.

With the International Commission on Radiological Protection (ICRP) lowering the annual dose limit for the eye lens to 20 mSv, precise monitoring of eye lens exposure has become essential. The personal dose equivalent at a depth of 3 mm, Hp(3), is the measurement method for monitoring the dose to the lens of the eye. Traditional dosimetry methods primarily address lateral radiation exposure scenarios, where radiation approaches from the left or right, necessitating the rotation of the phantom during type testing around the vertical axis.

View Article and Find Full Text PDF

Background: Optimal management of post-operative pain is a critical component of orthopedic surgical care. There is a heightened awareness of narcotic prescribing habits given the current "opioid epidemic." The lack of standardized protocols has led to increased errors, delayed access to prescribed medications, and excessive narcotic prescribing.

View Article and Find Full Text PDF

Purpose: Optimal treatment of retroperitoneal sarcoma (RPS) remains undefined. Here, we report the feasibility of using high-dose boost radiation (3-4 Gy) to the central part of the tumor in patients with unresectable RPS.

Methods And Materials: Five patients with unresectable RPS were treated with radiation therapy using a central boost technique with intensity modulated radiation therapy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!