System design and initial results are presented from a new unilateral MR-guided breast lesion localization and core biopsy system. Over 150 imaging studies, an accuracy study on phantoms with 50 localization wire deployments and 33 core biopsy trials, and 19 clinical procedures are reported. The mean spatial accuracy from the lesion center for a 20-gauge (G) needle (N = 13) was within 1.2 +/- 1.4 mm (SD) and for a 14G biopsy (N = 4) 0.8 +/- 1.1 mm. For sampling using a 16G core through a 14G needle, the mean accuracy was 5.6 mm (N = 2). The needle guide geometry imposed a small, calculable targeting error. For phantom measurements using the 20G device, the mean geometry-induced error was 0.73 +/- 0.43 mm. However, this contribution was, on average, 42% of the mean measured 2.35 +/- 1.65 mm offset. The new device design provided an accurate and simple guidance method for localization or core biopsy of MR-visible breast lesions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/jmri.1180 | DOI Listing |
Medicina (Kaunas)
December 2024
Department of Medical Oncology, Sanko University Medical Faculty Gaziantep Türkiye, Gaziantep 27090, Türkiye.
: Among breast cancer molecular types, HER2 positive and triple negative (TN) subtypes have the highest likelihood of pathological complete response (pCR), which is a surrogate marker for reduced recurrence and improved patient survival after neoadjuvant systemic treatment (NST). Preoperative pathological identification of these exceptional responders is a new era. Therefore, we aimed to determine the accuracy of trucut biopsy in identifying the exceptional responders in selected molecular subtypes of breast cancer patients.
View Article and Find Full Text PDFDiagnostics (Basel)
January 2025
Department of Radiology, "Iuliu Hatieganu" University of Medicine and Pharmacy, 400347 Cluj-Napoca, Romania.
Breast cancer is a leading cause of cancer-related mortality among women worldwide. Accurate staging, including the detection of axillary metastases, is vital for treatment planning. This study evaluates the efficacy of MRI relaxometry as a diagnostic tool for axillary lymph node metastases in breast cancer patients.
View Article and Find Full Text PDFJ Pers Med
January 2025
Multidisciplinary Breast Centre, Department of Women's and Children's Health Sciences and Public Health, Fondazione Policlinico Universitario A. Gemelli IRCCS, 00168 Rome, Italy.
B3 breast lesions, classified as lesions of uncertain malignant potential, present a significant diagnostic and therapeutic challenge due to their heterogeneous nature and variable risk of progression to malignancy. These lesions, which include atypical ductal hyperplasia (ADH), papillary lesions (PLs), flat epithelial atypia (FEA), radial scars (RSs), lobular neoplasia (LN), and phyllodes tumors (PTs), occupy a "grey zone" between benign and malignant pathologies, making their management complex and often controversial. This article explores the diagnostic difficulties associated with B3 lesions, focusing on the limitations of current imaging techniques, including mammography, ultrasound, and magnetic resonance imaging (MRI), as well as the challenges in histopathological interpretation.
View Article and Find Full Text PDFJ Gastroenterol
January 2025
Department of Gastroenterology and Hepatology, Graduate School of Medicine, Hokkaido University, Hokkaido, Japan.
Background: Advanced liver fibrosis in cases of metabolic dysfunction-associated steatotic liver disease (MASLD) leads to cirrhosis and hepatocellular carcinoma. The current gold standard for liver fibrosis is invasive liver biopsy. Therefore, a less invasive biomarker that accurately reflects the stage of liver fibrosis is highly desirable.
View Article and Find Full Text PDFBMJ Case Rep
January 2025
Orthopaedics, All India Institute of Medical Science - Bhopal, Bhopal, Madhya Pradesh, India.
This case revolves around a mid-childhood boy diagnosed with a chemoresistant chondroblastic osteosarcoma, a rare and aggressive form of bone tumour affecting his left proximal humerus. Histopathological confirmation of chondroblastic osteosarcoma was obtained through core-needle biopsy. Despite initiating cytoreductive neoadjuvant chemotherapy using a vincristine and cyclophosphamide regimen, the tumour exhibited resistance, prompting the decision to proceed with a forequarter amputation.