Radiology interventions in patients receiving low molecular weight heparin: timing is critical.

Australas Radiol

Division of Medical Imaging, Northwest Adelaide Health Services, The Queen Elizabeth Hospital Campus, 28 Woodville Road, Woodville, SA 5001, Australia.

Published: August 2001

Recent advances in diagnosis and treatment of venous thromboembolism have been associated with increasing use of low molecular weight heparins (LMWH) for treatment and prophylaxis of this disease. Despite this trend for more widespread use of LMWH, little is known of their safety in patients undergoing radiology interventions. Differences between LMWH and unfractionated heparin and the implications of these differences on use of LMWH in the setting of radiological interventions are outlined.

Download full-text PDF

Source
http://dx.doi.org/10.1046/j.1440-1673.2001.00927.xDOI Listing

Publication Analysis

Top Keywords

radiology interventions
8
low molecular
8
molecular weight
8
differences lmwh
8
interventions patients
4
patients receiving
4
receiving low
4
weight heparin
4
heparin timing
4
timing critical
4

Similar Publications

Background: For radiotherapy of head and neck cancer (HNC) magnetic resonance imaging (MRI) plays a pivotal role due to its high soft tissue contrast. Moreover, it offers the potential to acquire functional information through diffusion weighted imaging (DWI) with the potential to personalize treatment. The aim of this study was to acquire repetitive DWI during the course of online adaptive radiotherapy on an 1.

View Article and Find Full Text PDF

Background: /aims. Pseudoxanthoma Elasticum (PXE, OMIM 264800) is an autosomal, recessive, metabolic disorder characterized by progressive ectopic calcification in the skin, the vasculature and Bruch's membrane. Variants in the ABCC6 gene are associated with low plasma pyrophosphate (PPi) concentration.

View Article and Find Full Text PDF

Background: Fibrotic types of interstitial lung abnormalities seen on high-resolution computed tomography scans, characterised by traction bronchiolectasis/bronchiectasis with or without honeycombing, are predictors of progression and poor prognostic factors of interstitial lung abnormalities. There are no reports on the clinical characteristics of fibrotic interstitial lung abnormalities on high-resolution computed tomography scans. Therefore, we aimed to examine these clinical characteristics and clarify the predictive factors of fibrotic interstitial lung abnormalities on high-resolution computed tomography scans.

View Article and Find Full Text PDF

CT-sensitized nanoprobe for effective early diagnosis and treatment of pulmonary fibrosis.

J Nanobiotechnology

January 2025

Nurturing Center of Jiangsu Province for State Laboratory of AI Imaging & Interventional Radiology; Basic Medicine Research and Innovation Center of Ministry of Education, Medical School of Southeast University, 87 Dingjiaqiao, Nanjing, 210009, China.

Early diagnosis is critical for providing a timely window for effective therapy in pulmonary fibrosis (PF); however, achieving this remains a significant challenge. The distinct honeycombing patterns observed in computed tomography (CT) for the primary diagnosis of PF are typically only visible in patients with moderate to severe disease, often leading to missed opportunities for early intervention. In this study, we developed a nanoprobe designed to accumulate at fibroblastic foci and loaded with the CT sensitizer iodide to enable effective early diagnosis of PF.

View Article and Find Full Text PDF

Background: To analyze the effects of the positioning of a bolt in the femoral neck system (FNS) on the short-term outcomes of middle-aged and young adults with displaced femoral neck fractures (FNFs).

Methods: This was a retrospective study involving 114 middle-aged and young adults with displaced FNFs who were surgically treated with internal fixation via the FNS in the Department of Orthopedics, Suzhou Municipal Hospital, from December 2019 to January 2023. The degree of deviation of the central axis of the femoral head and neck from the tip of the bolt (W), the tip‒apex distance (TAD) and the length of femoral neck shortening (LFNS) were measured on postoperative X-ray and computed tomography (CT) scan images.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!