A silicon crystal was used to channel and extract 70 GeV protons from the U-70 accelerator with an efficiency of 85.3+/-2.8%, as measured for a beam of approximately 10(12) protons directed towards crystals of approximately 2 mm length in spills of approximately 2 s duration. The experimental data follow very well the prediction of Monte Carlo simulations. This demonstration is important in devising a more efficient use of the U-70 accelerator in Protvino and provides crucial support for implementing crystal-assisted slow extraction and collimation in other machines, such as the Tevatron, RHIC, the AGS, the SNS, COSY, and the LHC.

Download full-text PDF

Source
http://dx.doi.org/10.1103/PhysRevLett.87.094802DOI Listing

Publication Analysis

Top Keywords

extraction collimation
8
u-70 accelerator
8
high-efficiency beam
4
beam extraction
4
collimation channeling
4
channeling short
4
short bent
4
bent crystals
4
crystals silicon
4
silicon crystal
4

Similar Publications

Purpose: This study presents novel quality assurance (QA) approach for volumetric modulated arc therapy (VMAT) that leverages frame-by-frame electronic portal imaging device (EPID) images integrated into Mobius3D for accurate three-dimensional dose calculations.

Methods: Sequential EPID images for VMAT plans were acquired every 0.4-second by iView system and processed through iterative deconvolution to mitigate blurring from photon scattering.

View Article and Find Full Text PDF

The optical attenuation coefficient (AC), a crucial tissue parameter indicating the rate of light attenuation within a medium, enables quantitative analysis of tissue properties and facilitates tissue differentiation. Despite its growing clinical significance, accurate quantification of AC from optical coherence tomography (OCT) signals remains a pressing concern. This study comprehensively investigates the factors influencing the accuracy of quantitative AC extraction among existing OCT-based AC extraction algorithms.

View Article and Find Full Text PDF

Background: The use of endovascular procedures is becoming increasingly popular across multiple clinical domains. These procedures are generally performed under image guidance using an interventional c-arm x-ray system. Radiation exposure to both patients and interventional staff due to use of fluoroscopy is a health and occupational concern, but modifications to the interventional workflow to address radiation may come at the cost of procedure time or quality.

View Article and Find Full Text PDF

Purpose: This study aimed to determine the selection criteria for circular collimator (CC)- and multileaf collimator (MLC)-based stereotactic radiosurgery (SRS)/stereotactic radiotherapy (SRT) plans for brain metastases (BM) and benign intracranial disease (BID) in terms of geometric parameters using CyberKnife (CK).

Methods: Forty-eight and eighty-five patients with BM and BID, respectively, were included. Two plans using CC and MLC were created for each case.

View Article and Find Full Text PDF

The introduction of automatic tube current modulation (ATCM) has resulted in complex relationships between scanner parameters, patient body habitus, radiation dose, and image quality. ATCM adjusts tube current based on x-ray attenuation variations in the scan region, and overall patient dose depends on a combination of factors. This work aims to develop mathematical models that predict CT radiation dose and image noise in terms of attenuating diameter and all relevant scanner parameters.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!