Objective: The aim of this study was to evaluate additional error in estimating red cell loss during abdominal hysterectomy.
Methods: Eighty patients admitted consecutively for abdominal hysterectomy were recruited. The surgeries were done after heparinizing the suction tubing system to prevent clotting and reducing the vacuum pressure to reduce red cell lysis. At the end of the surgery, hematocrit was measured and compared with the patient's venous blood and the blood from the suction container. The Mann-Whitney test evaluated statistical significance.
Results: Eight patients were excluded for having a hemolyzed blood sample, receiving a blood transfusion, and having incomplete data. The study cohort consisted of 72 patients: 54 had a simple hysterectomy and 18 had a radical hysterectomy with pelvic and periaortic lymphadenectomy. The hematocrit (mean +/- standard deviation) in the suction container (19.8 +/- 8.8%) was lower than the hematocrit from the venous blood sample (32.4 +/- 6%) (P < 0.001). The hematocrit in the suction container decreased as the duration of the surgeries increased. Although the volume of blood in the suction container was used to estimate blood loss, the concentration of red cells in the container was consistently lower than those in the venous blood sample. The magnitude of dilution increased as the length and radical nature of the surgery increased.
Conclusions: These findings suggest that other fluid, probably lymph, contributes to the dilution of red cells in the container and increases the estimated blood volume loss during surgery. Estimation of red cell surgical blood loss becomes less accurate as the length and radical nature of the surgery increase.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1006/gyno.2001.6269 | DOI Listing |
Am J Obstet Gynecol MFM
January 2025
Department of Anaesthesiology and Critical Care, Jawaharlal Institute of Post Graduate Medical Education and Research, Puducherry, India (A.K. Jha). Electronic address:
Background: Preclinical studies have documented the role of alpha-adrenergic agonists in myometrial contraction. Phenylephrine is frequently used to prevent and treat post-spinal hypotension during cesarean delivery. We hypothesized phenylephrine would reduce postpartum blood loss due to alpha-1 receptor-mediated uterine and vascular smooth muscle contraction.
View Article and Find Full Text PDFJ Colloid Interface Sci
April 2025
School of Minerals Processing and Bioengineering, Central South University, Changsha 410083, PR China. Electronic address:
The ecological risk of microplastics (MPs) is raising concern about their transport and fate in aquatic ecosystems. The capture of MPs by bubbles is a ubiquitous natural phenomenon in water-based environment, which plays a critical role in the global cycling of MPs, thereby increasing their environmental threats. However, the nanoscale interaction mechanisms between bubbles and MPs underlying MPs transport by bubbles in complex environmental systems remain elusive.
View Article and Find Full Text PDFBMC Anesthesiol
December 2024
Department of Anesthesiology, West China Second University Hospital, Sichuan University, Chengdu, 610041, Sichuan, P. R. China.
Background: Delayed gastric emptying of liquids may heighten the risk of aspiration reflux in elderly individuals. To investigate the gastric emptying of an oral supplement containing 5% dextrose solutions before sedation for gastroscopy.
Patients And Methods: A total of 100 elderly patients who were scheduled for elective gastroscopy were randomly assigned to two groups: the NPO(nil per os ) group and the dextrose solution ingestion group, which ingested a 5% dextrose solution (5 ml/kg) two hours before the procedure.
Cureus
October 2024
Department of Oral and Maxillofacial Surgery, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, JPN.
One of the causes of ventilator-associated pneumonia (VAP) is the aspiration of fluid-containing pathogenic bacteria into the lower respiratory tract. The purpose of this study was to determine whether oral povidone-iodine (PV-I) application reduces bacterial counts in the fluid on the cuff of an endotracheal intubation tube. Patients intubated and managed with tracheostomy for oral cancer surgery were divided into two groups.
View Article and Find Full Text PDFObes Surg
December 2024
Department of Surgery, West Virginia University School of Medicine, 64 Medical Center Drive, PO BOX 9238, Morgantown, WV, 26506, USA.
Purpose: The study objective was to identify variations in calibration tube use during sleeve gastrectomy and understand elements of ideal calibration tube performance.
Materials And Methods: A survey was distributed via email and social media to bariatric surgeons, who were asked to rate the performance of their current calibration tube and an ideal calibration tube for five technical milestones involving visualization, positioning, suction capability, and sleeve sizing. Data was analyzed using descriptive and bivariate analyses including chi-square, Mann-Whitney, and Kruskal-Wallis tests.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!