Measurement of depth of burns by laser Doppler perfusion imaging.

Burns

The Burns Unit, Dept. of Hand and Plastic Surgery, the University Hospital, Linköping, Sweden.

Published: September 2001

Laser Doppler perfusion imaging (LDPI), is a further development in laser Doppler flowmetry (LDF). Its advantage is that it enables assessment of microvascular blood flow in a predefined skin area rather than, as for LDF, in one place. In many ways this method seems to be more promising than LDF in the assessment of burn wounds. However, several methodological issues that are inherent in the LDPI technique, and are relevant for the assessment of burn depth, must be clarified. These include the effect of scanning distance, curvature of the tissue, thickness of topical wound dressings, and pathophysiological effects of skin colour, blisters, and wound fluids. Furthermore, we soon realised that to examine the perfusion image generated by LDPI adequately the process of analysis was appreciably improved by the simultaneous use of digital photography. In the present investigation we used both in vitro and in vivo models and also examined burned patients, and found that the listed factors all significantly affected the LDPI output signal. However, if these factors are known to the examiner, most of them can be adjusted for. If the technique is further improved by minimizing such effects and by reducing the practical difficulties of applying it to a burned patient in the burns unit, the technique may find uses in everyday clinical decision-making.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0305-4179(01)00021-3DOI Listing

Publication Analysis

Top Keywords

laser doppler
12
doppler perfusion
8
perfusion imaging
8
assessment burn
8
measurement depth
4
depth burns
4
burns laser
4
imaging laser
4
ldpi
4
imaging ldpi
4

Similar Publications

Capillary Wave-Assisted Colloidal Assembly.

Langmuir

January 2025

Cain Department of Chemical Engineering, Louisiana State University, Baton Rouge, Louisiana 70803, United States.

The self-assembly of nanoparticle colloids into large-area monolayers with long-range order is a grand challenge in nanotechnology. Using acoustic energy, i.e.

View Article and Find Full Text PDF

The work is devoted to the study of the physiological variability of the microcirculatory-tissue system (MTS) parameters under normal conditions and during functional tests. The results were obtained in vivo using multimodal wearable analyzers implementing methods of laser Doppler flowmetry and fluorescence spectroscopy. Comprehensive data analysis and calculation of the coefficients of variation of the MTS parameters of the human body for various topographic and anatomical areas of the skin were carried out.

View Article and Find Full Text PDF

Mid-infrared dual-comb spectroscopy offers significant advantages by combining the high sensitivity of mid-infrared spectroscopy with the high spectral resolution and rapid acquisition of the dual-comb method. However, its effective resolution, constrained by the inherent comb line spacing, hinders its ability to resolve narrow absorption features, common in critical applications such as sub-Doppler spectroscopy, low-pressure gas analysis, and construction of the atmospheric profile. To address this challenge, we present a synchronous offset frequency tuning method for the mid-infrared dual-comb system to improve effective resolution far beyond comb line spacing.

View Article and Find Full Text PDF

We present a dual isotope magneto-optical trap (MOT), simultaneous sub-Doppler laser cooling, and magnetic trapping of a spin-polarized K-K Bose-Fermi mixture realized in a single-chamber setup with an unenriched potassium dispenser as the source of atoms. We are able to magnetically confine more than 2.2 × 10 fermions ( = 9/2 ,  = 9/2) and 1.

View Article and Find Full Text PDF

Monitoring of perioperative tissue perfusion and impact on patient outcomes.

J Cardiothorac Surg

January 2025

Department of Anesthesiology, Zhongda hospital, Southeast University, No. 87 Dingjiaqiao, Nanjing City, 210009, Jiangsu Province, China.

Monitoring perioperative tissue perfusion is crucial in clinical anesthesia to protect organs and ensure patient safety. Indicators like hemodynamic parameters, tissue metabolism, and microcirculation markers are used for assessment. Studies show intraoperative hypotension negatively impacts outcomes, though blood pressure alone may not reflect tissue perfusion accurately.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!