Background: There are limited data regarding the immediate and long-term effect of balloon angioplasty on the coronary flow reserve evaluated in a multicentre setting.

Methods And Results: A total of 86 patients with one-vessel disease and normal left ventricular function were analysed before and after optimal balloon angioplasty (diameter stenosis <35%) and at 6-month follow-up. Coronary flow reserve was assessed with a Doppler guide wire. A low coronary flow reserve (2.5 (46% vs 23% and 36% vs 16%, respectively; P<0.05) due to a trend towards restenosis (29% vs 16%; P=0.15) or a low coronary flow reserve at follow-up due to persistent elevated baseline blood flow velocity. Patients without restenosis showed a decrease or increase of coronary flow reserve during follow-up, determined by alterations of hyperaemic blood flow velocity.

Conclusions: Patients with an impaired coronary flow reserve directly after optimal balloon angioplasty showed a higher target lesion revascularization rate compared to patients with a coronary flow reserve >2.5. This patient group consists of patients prone to develop restenosis, while other patients are characterized by a persistently low coronary flow reserve, probably secondary to disturbed autoregulation and/or diffuse mild coronary atherosclerosis. Coronary flow reserve alterations in patients without restenosis were related to changes in hyperaemic blood flow velocity, suggesting that this phenomenon relates to epicardial remodelling.

Download full-text PDF

Source
http://dx.doi.org/10.1053/euhj.2000.2587DOI Listing

Publication Analysis

Top Keywords

balloon angioplasty
16
optimal balloon
8
long-term optimal
4
balloon
4
angioplasty
4
angioplasty absolute
4
absolute coronary
4
coronary blood
4
blood flow
4
flow velocity
4

Similar Publications

Background: Due to the heterogeneity of literature findings, stent type selection for the endovascular treatment of complex aorto-iliac occlusive disease remains challenging. The BELSTREAM study, a physician-initiated, prospective, multicenter, single-arm study, aims to report the safety and efficacy of the balloon expandable LifeStream Peripheral Stent Graft System (BD, Tempe, Arizona, USA) for the treatment of complex TASC C and D aorto-iliac artery lesions.

Methods: Seventy patients and 133 lesions were included at six Belgian institutions.

View Article and Find Full Text PDF

Optimizing the life of vascular access during follow-up.

J Cardiovasc Surg (Torino)

February 2025

Department of Vascular Surgery, ASST Settelaghi Universitary Teaching Hospital, University of Insubria, Varese, Italy.

Optimizing the longevity of vascular access in hemodialysis patients remains a critical aspect of patient care, given the significant role of arteriovenous fistulas (AVFs) and arteriovenous grafts (AVGs) in enabling effective dialysis. Vascular access complications, such as stenosis, thrombosis, and cannulation-related damage, continue to challenge both the functionality and the sustainability of these access points. Recent advancements underscore the importance of a robust follow-up strategy, integrating clinical evaluations with diagnostic tools like color Doppler ultrasound (CDU) and emerging interventional approaches such as drug-coated balloon (DCB) angioplasty.

View Article and Find Full Text PDF

Background: This study aimed to investigate the clinical outcomes of percutaneous transluminal angioplasty (PTA) in patients undergoing hemodialysis with different types of superior vena cava obstruction (SVCO) lesions.

Methods: This retrospective observational study recruited patients undergoing hemodialysis with SVCO and analyzed the clinical characteristics of SVCO. Patency rates were collected for patients treated with PTA and were assessed using the t-test, U-test, log-rank test and survival analyses such as the Kaplan-Meier method.

View Article and Find Full Text PDF

Pulmonary arterial hypertension (PAH) is a long-term condition characterised by increased resistance to blood flow in the pulmonary circulation. The disease has a progressive course and is associated with a poor prognosis. Without treatment, PAH is associated with mortality in <3 years.

View Article and Find Full Text PDF

Background: Multisystem inflammatory syndrome in neonates (MIS-N) is a rare condition thought to be associated with prenatal exposure to maternal severe acute respiratory syndrome coronavirus 2 infection. This immune-mediated hyperinflammation has been described in neonates with multiorgan dysfunction, including cardiopulmonary, encephalopathy, coagulopathy, and vascular complications. However, renovascular complications in MIS-N are rare.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!