Objective: To determine whether fluoride releasing elastomeric modules reduced the incidence of decalcification around orthodontic brackets during a complete course of orthodontic treatment.
Design: A randomised controlled, split mouth design.
Setting: The study was carried out in the orthodontic department of Newcastle-upon-Tyne Dental Hospital, UK.
Subject And Methods: 21 consecutive patients (126 teeth) undergoing fixed appliance therapy were studied. A split mouth technique was adopted to examine the upper labial segment, where one side (left or right) was randomly assigned to the experimental group, and the opposite side served as a control throughout their course of orthodontic treatment.
Interventions: The control teeth were ligated to the archwire using conventional modules. The experimental teeth were ligated to the archwire using Fluoride releasing elastomeric modules.
Outcome Measures: Standardised photographs were taken of the upper labial segment before and after completion of orthodontic treatment, and the degree of decalcification assessed in each tooth quadrant, using a modification of the Enamel Defect Score.
Results: Decalcification was found to occur in both treatment groups, though to a significantly greater degree on the control side (p = 0.002). The fluoride module side showed significantly fewer serious decalcified lesions than the control (p = 0.013). No patients withdrew from the study.
Conclusions: It would appear that the use of fluoride releasing elastomeric modules reduces the degree of decalcification experienced during orthodontic treatment.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/ortho/28.3.217 | DOI Listing |
Cureus
September 2024
Orthodontics and Dentofacial Orthopedics, Ranjeet Deshmukh Dental College and Research Centre, Nagpur, IND.
Introduction: Canine retraction is critical in orthodontic treatment, requiring precise force application. Elastomeric chains and active tiebacks are commonly used materials, but their efficacy in maintaining the force over time needs further evaluation. The study aimed to compare the rate of force degradation of elastomeric chains vs.
View Article and Find Full Text PDFACS Appl Mater Interfaces
October 2024
School of Future Science and Engineering, Soochow University, Suzhou 215123, China.
Wearable human-machine interface (HMI) with bidirectional and multimodal tactile information exchange is of paramount importance in teleoperation by providing more intuitive data interpretation and delivery of tactilely related signals. However, the current sensing and feedback devices still lack enough integration and modalities. Here, we present a Tactile Sensing and Rendering Patch (TSRP) that is made of a customized expandable array which consists of a piezoelectric sensing and feedback unit fused with an elastomeric triboelectric multidimensional sensor and its inner pneumatic feedback structure.
View Article and Find Full Text PDFLab Chip
September 2024
Bioengineering Program, The University of Kansas, Lawrence, KS 66045, USA.
Microfluidic systems combine multiple processing steps and components to perform complex assays in an autonomous fashion. To enable the integration of several bio-analytical processing steps into a single system, valving is used as a component that directs fluids and controls introduction of sample and reagents. While elastomer polydimethylsiloxane has been the material of choice for valving, it does not scale well to accommodate disposable integrated systems where inexpensive and fast production is needed.
View Article and Find Full Text PDFCureus
June 2024
Department of Orthodontics, Bharati Vidyapeeth (Deemed to be University) Dental College and Hospital, Navi Mumbai, IND.
Introduction Orthodontic mechanics involves transferring some of the applied force to the tooth's supporting components via friction, which in turn allows the tooth to move more easily. Aim The purpose of this in vitro experiment was to examine the frictional resistance (FR) of different lingual brackets utilizing Instron universal testing machines and nitinol (NiTi) archwires of varying sizes. Materials and methods Twenty-four sectional anterior die stones were replicated from a study model.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!