A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Calibration of Polarization-Sensitive and Dual-Angle Laser Light Scattering Methods Using Standard Latex Particles. | LitMetric

Calibration of Polarization-Sensitive and Dual-Angle Laser Light Scattering Methods Using Standard Latex Particles.

J Colloid Interface Sci

Department of Chemical Engineering, Graduate School of Engineering, Hiroshima University, 1-4-1, Kagamiyama, Higashi-Hiroshima, 739-8527, Japan

Published: September 2001

A polarization-sensitive laser light scattering (PSLLS) method and a dual-angle laser light scattering (DALLS) method have been studied for in situ measurement of submicrometer hydrosol and aerosol particles. By using standard monodisperse polystyrene latex particles suspended in water and air as test particles, calibration of systems built based on the above methods have been performed. The effects of light scattered by agglomerated aerosol particles (multiplets) were corrected by considering the fraction of multiplets as determined with an aerosol measurement technique using a differential mobility analyzer. The change in the measured intensities of scattered light with particle diameter was then determined by calculations based on Mie theory. It was shown that the PSLLS system can determine particle diameters as small as approximately 60 nm for the test hydrosol particles and approximately 100 nm for test aerosol particles, respectively. The DALLS system can determine smaller diameters than the PSLLS system for test particles with no light absorption. The change in scattered light intensities with particle diameter was also investigated by theoretical calculations with various refractive indexes and scattering angles. The PSLLS and DALLS systems promise to become routine measurement tools for absorbing and nonabsorbing particles, respectively. Copyright 2001 Academic Press.

Download full-text PDF

Source
http://dx.doi.org/10.1006/jcis.2001.7707DOI Listing

Publication Analysis

Top Keywords

laser light
12
light scattering
12
aerosol particles
12
particles
9
dual-angle laser
8
latex particles
8
test particles
8
scattered light
8
particle diameter
8
pslls system
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!