Recirculation is a limiting factor for oxygen delivery in double lumen catheter veno-venous extracorporeal membrane oxygenation (DLVV-ECMO). This study compares three different methods for the determination of the recirculation fraction during double lumen catheter veno-venous ECMO at ECMO flow rates of 150, 125, 100, 75, and 50 ml/kg.min in nine lambs: (1) an ultrasound dilution method, in which the change in ultrasound velocity in blood after injection of a saline bolus as a marker is used for determination of recirculation; (2) an SvO2 method using real mixed venous blood oxygen saturation, the gold standard, for determination of recirculation fraction; and (3) the CVL method, in which oxygen saturation of a blood sample of the inferior vena cava is considered to represent mixed venous oxygen saturation. In all methods, the recirculation fraction increased with increasing ECMO flow rate. The correlation coefficient between the ultrasound dilution method and the SvO2 method was 0.68 (p < 0.01); mean difference was -2.4% (p = 0.6). Correlation coefficient between the ultrasound dilution method and the CVL method was 0.48 (p < 0.01); mean difference was -18.1% (p < 0.01). The correlation coefficient between the SvO2 method and the CVL method was 0.51 (p < 0.01); mean difference was -15.7% (p < 0.01). The ultrasound dilution method is a useful method for measurement of the recirculation fraction in DLVV-ECMO and is easier to use than the other methods.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00002480-200107000-00015DOI Listing

Publication Analysis

Top Keywords

ultrasound dilution
20
recirculation fraction
16
dilution method
16
double lumen
12
lumen catheter
12
catheter veno-venous
12
determination recirculation
12
svo2 method
12
oxygen saturation
12
cvl method
12

Similar Publications

Introduction: Veno-venous extracorporeal membrane oxygenation (V-V ECMO) is increasingly used in the treatment of severe respiratory failure. Despite a significant increase in the worldwide use of extracorporeal lung assist devices recirculation remains a common complication and is associated with a reduced effectiveness of ECMO support and increased hemolysis. In this observational study we aimed to investigate the impact of cannula configuration and extracorporeal flow on recirculation.

View Article and Find Full Text PDF

In recent years, significant advancements in respiratory and nutritional care have markedly improved the survival rates of preterm infants and enhanced long-term health outcomes. Despite these improvements, emerging research highlights the lasting impacts of early growth patterns on an individual's health trajectory. Adults born prematurely face a higher incidence of health issues related to their early birth.

View Article and Find Full Text PDF

Aims: Coronary microvascular dysfunction (CMD) is a heterogeneous condition defined by reduced coronary flow reserve (CFR). The new index 'microvascular resistance reserve' (MRR) has been developed, but its role is unclear. We investigate the relationships between functional indices in ANOCA (angina and non-obstructive coronary arteries) patients and evaluate the hemodynamic features of different CMD subtypes.

View Article and Find Full Text PDF

The cooling procedure markedly diminishes the quality of guinea pig () sperms, primarily because their membranes are highly susceptible to this process. This susceptibility triggers the generation of reactive oxygen species and free radicals, ultimately leading to lipid peroxidation in the sperm membrane. Surprisingly, there has been a lack of research on the use of Tris-based extenders to safeguard guinea pig sperm under refrigeration conditions.

View Article and Find Full Text PDF

Objective: To assess the agreement of transpulmonary thermodilution (TPTD) and transpulmonary ultrasound dilution (TPUD) against direct measurement of main pulmonary artery flow with an ultrasound transit time flow probe (UTF) over a wide range of conditions in anesthetized cats. Additionally, the trending ability of TPTD, TPUD, and esophageal Doppler ultrasonography (EDU) was evaluated against UTF.

Methods: 12 purpose-bred cats were used.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!