Biomimetic finger control by filtering of distributed forelimb pressures.

IEEE Trans Neural Syst Rehabil Eng

Orthotic and Prosthetic Laboratory, Department of Biomedical Engineering, Rutgers University, Piscatway, NJ 08854, USA.

Published: March 2001

A linear filter was developed for decoding finger commands from volitional pressures distributed within the residual forelimb. Filter parameters were based on dynamic pressures recorded from the residual limb within its socket, during specific finger commands. A matrix of signal features was derived from eight-dimensional (8-D) pressure vectors, and its pseudoinverse comprised the filter parameters. Results with amputees showed that the filter could discriminate specific finger flexion commands, suggesting that pressure vector decoding (PVD) can provide them with biomimetic finger control.

Download full-text PDF

Source
http://dx.doi.org/10.1109/7333.918278DOI Listing

Publication Analysis

Top Keywords

biomimetic finger
8
finger control
8
finger commands
8
filter parameters
8
specific finger
8
control filtering
4
filtering distributed
4
distributed forelimb
4
forelimb pressures
4
pressures linear
4

Similar Publications

Significance: Pulse oximeter measurements are commonly relied upon for managing patient care and thus often require human testing before they can be legally marketed. Recent clinical studies have also identified disparities in their measurement of blood oxygen saturation by race or skin pigmentation.

Aim: The development of a reliable bench-top performance test method based on tissue-simulating phantoms has the potential to facilitate pre-market assessment and the development of more accurate and equitable devices.

View Article and Find Full Text PDF

Research on Multimodal Control Method for Prosthetic Hands Based on Visuo-Tactile and Arm Motion Measurement.

Biomimetics (Basel)

December 2024

Institute of Instrument Science and Engineering, Southeast University, Nanjing 210096, China.

Article Synopsis
  • The research focuses on enhancing robotic hand function to assist disabled individuals, leveraging advanced multimodal perception and control methods.
  • Key techniques include using a pinhole camera and YOLOv8 for object recognition, along with multi-frame data and clustering algorithms to ensure accurate grasping by the robotic hand.
  • The resulting system achieves a high grasping success rate of 91.63% while maintaining user comfort, demonstrating its effectiveness and potential for real-world application.
View Article and Find Full Text PDF

High-performance eco-friendly soft actuators showing large displacement, fast response, and long-term operational capability require further development for next-generation bioinspired soft robots. Herein, we report an electro-ionic soft actuator based on carboxylated cellulose nanocrystals (CCNC) and carboxylated cellulose nanofibers (CCNF), graphene nanoplatelets (GN), and ionic liquid (IL). The actuator exhibited exceptional actuation performances, achieving large displacements ranging from 1.

View Article and Find Full Text PDF

Non-physiological levels of oxygen and nutrients within the tumors result in heterogeneous cell populations that exhibit distinct necrotic, hypoxic, and proliferative zones. Among these zonal cellular properties, metabolic rates strongly affect the overall growth and invasion of tumors. Here, we report on a hybrid discrete-continuum (HDC) mathematical framework that uses metabolic data from a biomimetic two-dimensional (2D) in-vitro cancer model to predict three-dimensional (3D) behaviour of in-vitro human glioblastoma (hGB).

View Article and Find Full Text PDF

Background: Human artificial corneas (HAC) generated by tissue engineering recently demonstrated clinical usefulness in the management of complex corneal diseases. However, the biological mechanisms associated to their regenerative potential need to be elucidated.

Methods: In the present work, we generated HAC using nanostructured fibrin-agarose biomaterials with cultured corneal epithelial and stromal cells, and we compared the structure and histochemical and immunohistochemical profiles of HAC with control native corneas (CTR-C) and limbus (CTR-L) to determine the level of biomimicry of the HAC with these two native organs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!