[Bone segment transport of the femur. Biomechanical value of an unreamed titanium intramedullary nail with reference to stiffness of external distraction systems].

Unfallchirurg

Klinik für Unfall- und Wiederherstellungschirurgie, Unfallkrankenhaus Berlin, Warener Strasse 7, 12683 Berlin.

Published: June 2001

The influence of an unreamed femur nail on axial and torque stiffness of nine different external fixator devices was investigated in a biomechanical study. With a newly developed femur bone model simulating segmental transport, 582 biomechanical tests were performed. The additional use of an unreamed femur nail (UFN) increased axial stiffness of the external fixator devices up to 8108% (average 1673.8-2631.8%) and increased torque stiffness up to 86% (average 47%). The best results could be achieved when combining a small-diameter UFN (9 x 360 mm, Synthes Co.) and external fixator devices with high torque and comparatively little axial stiffness. The use of stainless steel half-pins instead of titanium half-pins improved torque stiffness significantly. Concerning the biomechanical demands made on external fixator devices used for femoral segmental transport, the Hexfix fixator with steel bar and steel half-pins combined with an UFN achieved the best results.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s001130170112DOI Listing

Publication Analysis

Top Keywords

external fixator
16
fixator devices
16
stiffness external
12
torque stiffness
12
unreamed femur
8
femur nail
8
segmental transport
8
axial stiffness
8
steel half-pins
8
stiffness
6

Similar Publications

Objective: Investigating the clinical efficacy of treating dorsally displaced distal radial double-column Die-punch fractures using a dorsal approach external fixator combined with Kirschner wires.

Methods: Retrospectively analyzed the clinical data of 15 patients with distal radial double-column Die-punch fractures treated with an external fixator combined with Kirschner wire between July 2020 and January 2023. There were 10 males and 5 females;6 cases on the left side and 9 on the right;age ranged from 22 to 76 years old.

View Article and Find Full Text PDF

Objective: Meta-analysis of the clinical efficacy of plate and external fixator fixation in the treatment of AO-C type distal radius fractures.

Methods: PubMed, Embase, Cochrane Medical Library, Web of Science, CNKI, Wanfang, VIP and SinoMed databases were searched for all literature on randomized controlled clinical trials of AO-C distal radius fractures. The search time limits were from each database.

View Article and Find Full Text PDF

Objective: To investigate the short-term clinical effect of closed reduction single arm external fixator combined with percutaneous needle fixation in the treatment of C1 distal radius fracture in elderly patients.

Methods: Between December 2022 and December 2023, a total of 60 elderly patients diagnosed with type C1 distal radius fractures were treated, comprising 9 males and 51 females. The age ranged from 65 to 84 years old, with an average of (72.

View Article and Find Full Text PDF

Objective: To evaluate the short-term clinical efficacy of external fixation and internal fixation with steel plate in the treatment of unstable distal radius fractures (AO-23C type), based on the principles of Chinese osteosynthesis (CO).

Methods: Forty-eight patients with unstable distal radius fractures between January 2022 and February 2023 were retrospectively analyzed and divided into the CO external fixation group and internal fixation group. CO external fixation group consisted of 25 patients, including 7 males and 18 females, aged from 37 to 56 years old with an average of ( 52.

View Article and Find Full Text PDF

Objective: To describe the characteristics of short arm deformity in patients with achondroplasia, and summarize the progress of its lenthening and reconstruction, so as to provide reference for clinical diagnosis and treatment.

Methods: The literature on the lenthening of upper limb with achondroplastic short arm deformity at home and abroad in recent years was reviewed, and the characteristics, extension methods, postoperative management, effectiveness evaluation, and related complications of short arm deformity were summarized.

Results: Achondroplastic short arm deformity affect the patient's daily perineal hygiene activities.

View Article and Find Full Text PDF