Objective: To study the relation between moderate coronary dissections, coronary flow velocity reserve (CFVR), and long term outcome.

Methods: 523 patients undergoing balloon angioplasty and sequential intracoronary Doppler measurements were examined as part of the DEBATE II trial (Doppler endpoints balloon angioplasty trial Europe). After successful balloon angioplasty, patients were randomised to stenting or no further treatment. Dissections were graded at the core laboratory by two observers and divided into four categories: none, mild (type A-B), moderate (type C), severe (types D to F). Patients with severe dissections (n = 128) or without available reference vessel CFVR (n = 139) were excluded. The remaining 256 patients were divided into two groups according to the presence (group A, n = 45) or absence (group B, n = 211) of moderate dissection.

Results: Following balloon angioplasty, there was no difference in CFVR between the two groups. At 12 months follow up, a higher rate of major adverse cardiac events was observed overall in group A than in group B (10 (22%) v 23 (11%), p = 0.041). However, the risk of major adverse events was similar in the subgroups receiving balloon angioplasty (group A, 6 (19%) v group B, 16 (16%), NS). Among group A patients, the adverse events risk was greater in those randomised to stenting (odds ratios 6.603 v 1.197, p = 0.046), whereas there was no difference in risk if the group was analysed according to whether the CFVR was < 2.5 or >/= 2.5 after balloon angioplasty.

Conclusions: Moderate dissections left untreated result in no increased risk of major adverse cardiac events. Additional stenting does not improve the long term outcome.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1729873PMC
http://dx.doi.org/10.1136/heart.86.2.193DOI Listing

Publication Analysis

Top Keywords

balloon angioplasty
24
major adverse
12
moderate coronary
8
long term
8
randomised stenting
8
group
8
adverse cardiac
8
cardiac events
8
risk major
8
adverse events
8

Similar Publications

It has been recognized for decades that dissections occur as a mechanism of balloon angioplasty. A successful angioplasty result contains some degree of intimal splitting and disruption, which usually heals well. Nonetheless, some dissections are extensive, leading to serious ischaemic complications.

View Article and Find Full Text PDF

A 66-year-old transfeminine patient presented to our institution with a central-venous stenosis causing dysfunction of her arteriovenous (AV) graft on her left arm. The patient was treated repeatedly, because of restenosis. Due to complete occlusion of the graft and subclavian vein as well as a liquid tumor located around the stenotic segment of the vein, we resected the left subclavian vein via a trap-door thoracotomy and inserted a PTFE-graft.

View Article and Find Full Text PDF

Background: Previous studies have shown that when thrombectomy has failed, rescue intracranial stenting is associated with better clinical outcomes compared with failed reperfusion. However, comparative data regarding stent type are lacking.

Objective: To compare the procedural and clinical outcomes of balloon-mounted stents (BMS) with those of self-expandable stents (SES).

View Article and Find Full Text PDF

Objective: Carotid artery disease is a major cause of stroke for which the standard treatment has traditionally been a combination of medical management and intervention, including both carotid endarterectomy (CEA) and transfemoral carotid artery stenting (TF-CAS). In recent years, transcarotid artery revascularization (TCAR) has been adopted as a promising treatment following FDA approval in 2015. In terms of stroke reduction, TCAR has been found to have equivalent outcomes with CEA with shorter operative times.

View Article and Find Full Text PDF

Background: Due to the heterogeneity of literature findings, stent type selection for the endovascular treatment of complex aorto-iliac occlusive disease remains challenging. The BELSTREAM study, a physician-initiated, prospective, multicenter, single-arm study, aims to report the safety and efficacy of the balloon expandable LifeStream Peripheral Stent Graft System (BD, Tempe, Arizona, USA) for the treatment of complex TASC C and D aorto-iliac artery lesions.

Methods: Seventy patients and 133 lesions were included at six Belgian institutions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!