Management of arterial access sites following percutaneous endovascular procedures is associated with patient discomfort and local complications. A new vascular sealing device, comprised of a balloon delivery catheter and a flowable procoagulant consisting of thrombin and collagen, was tested. Immediately following catheterization 200 patients (age, 66.1 +/- 11.2 years) were treated with the sealing device (Duett). Of these 200 patients, 132 underwent diagnostic catheterization, 67 underwent percutaneous transluminal coronary angioplasty, and one underwent percutaneous transluminal angioplasty. The sheath sizes included 2-5 Fr, 166-6 Fr, 25-7 Fr and 7-8 Fr. All patients undergoing diagnostic procedures received at least 5,000 U of intravenous heparin during the procedure. The Duett was used successfully in 198/200 (99%) patients immediately following completion of the endovascular procedure. In two patients a device malfunction resulted in uncomplicated crossover to manual compression. The time to hemostasis ranged from 3 to 5 minutes. All patients were walking 2 to 5 hours following the procedure unless a complication had occurred. No patient experienced leg ischemia, required surgical repair of the arterial access site, or had an infection at the site. In three patients (1.5%), a pseudoaneurysm occurred and was successfully treated with ultrasound-guided compression and three patients received a blood transfusion. No late complications were observed following hospital discharge. This novel vascular sealing device successfully achieves rapid hemostasis and allows early ambulation following percutaneous endovascular procedures with a low incidence of complications.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/153857440103500306 | DOI Listing |
Ann Vasc Surg
January 2025
Department of Vascular Surgery, University Medical Center Utrecht, Utrecht, The Netherlands. Electronic address:
Introduction: Aorto-bronchial or aorto-pulmonary fistulas (ABPF) are a rare but life-threatening complication following thoracic endovascular aortic repair (TEVAR). This narrative review aims to provide an overview of the current trends and available evidence on ABPF following TEVAR, evaluating risk factors, diagnostic approaches, and possible preventive and therapeutic strategies.
Methods: Relevant publications on post-TEVAR ABPF were selected through a literature search on PubMed.
PLoS One
January 2025
Aesthetic and Restorative Dentistry Department, College of Dentistry, University of Baghdad, Baghdad, Iraq.
This study evaluated the extent to which obturation materials bypass fractured endodontic instruments positioned in the middle and apical thirds of severely curved simulated root canals using different obturation techniques. Sixty resin blocks with simulated root canals were used, each with a 50° curvature, a 6.5 mm radius of curvature, and a length of 16.
View Article and Find Full Text PDFJ Funct Biomater
January 2025
Jiangsu Key Laboratory for Advanced Metallic Materials, School of Materials Science and Engineering, Southeast University, Nanjing 211189, China.
Antibacterial stainless steels have been widely used in biomedicine, food, and water treatment. However, the current antibacterial stainless steels face challenges in balancing corrosion resistance and antibacterial effectiveness, limiting their application range and lifespan. In this study, an oxide layer sealed with antibacterial Ag particles was constructed on the surface of 304 stainless steel through anodizing and electrodeposition, and the process parameters were optimized for achieving long-term antibacterial properties.
View Article and Find Full Text PDFJ Hazard Mater
January 2025
Monash Lung, Sleep, Allergy and Immunology, Monash Health, Melbourne, VIC, Australia; School of Clinical Sciences, Monash University, Melbourne, VIC, Australia; Monash Partners - Epworth, Melbourne, VIC, Australia.
Mitigation measures against infectious aerosols are desperately needed. We aimed to: 1) compare germicidal ultraviolet radiation (GUV) at 254 nm (254-GUV) and 222 nm (222-GUV) with portable high efficiency particulate air (HEPA) filters to inactivate/remove airborne bacteriophage ϕX174, 2) measure the effect of air mixing on the effectiveness of 254-GUV, and 3) determine the relative susceptibility of ϕX174, SARS-CoV-2, and Influenza A(H3N2) to GUV (254 nm, 222 nm). A nebulizer generated ϕX174 laden aerosols in an occupied clinical room (sealed-low flow).
View Article and Find Full Text PDFClin Implant Dent Relat Res
February 2025
Minnesota Dental Research Center for Biomaterials and Biomechanics, School of Dentistry, University of Minnesota, Minneapolis, Minnesota, USA.
Objectives: This study evaluated different designs of the conical implant-abutment connection (IAC) and their resistance to microgap formation under oblique loads as specified by the ISO standard for testing dental implants. Also evaluated was the effect of deviations from the ISO specifications on the outcomes.
Methods: Finite element analysis was conducted to compare the microgap formation and stress distribution among three conical IAC designs (A, B, and C) in two loading configurations: one compliant with ISO 14801 and one with a modified load adaptor (non-ISO).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!