The acute hemodynamic effect of atrioventricular (AV) and inter/intraventricular (IV) resynchronization accomplished by temporary pacing using multiple epicardial pacing wires was evaluated in 20 children (aged 3.4 months to 14.0 years) after surgery for congenital heart defects fulfilling the following criteria: (1) presence of AV and/or IV conduction delay, and (2) need for inotropic support. AV resynchronization (n = 13) was achieved by AV delay optimization during atrial synchronous right ventricular outflow tract pacing. IV resynchronization (n = 14) was accomplished by atrial synchronous pacing from the right ventricular lateral wall in 7 patients with right bundle branch block and normal AV conduction and by atrial synchronous multisite ventricular pacing in another 7 patients with previously performed AV resynchronization. Compared with baseline values, AV resynchronization resulted in an increase in arterial systolic, mean, and pulse pressures by 7.2 +/- 8.3% (p <0.01), 8.6 +/- 8.1% (p <0.005), and 6.9 +/- 13.5% (p = NS), respectively. IV resynchronization used either alone or added to previously performed AV resynchronization led to a pressure increase of 7.0 +/- 4.7%, 5.9 +/- 4.7%, and 9.4 +/- 7.8%, respectively (p <0.001 for all). The combined effect of AV and IV resynchronization resulted in a systolic, mean, and pulse pressure increase of 10.2 +/- 5.0% (range 4.0 to 19.1), 8.6 +/- 5.4% (range 0.8 to 14.8), and 15.2 +/- 8.5% (range 6.1 to 33.3), respectively (p <0.001 for all). The increase in systolic arterial pressure after IV resynchronization was positively correlated with the initial QRS duration (r = 0.62, p <0.05) and extent of QRS shortening (r = 0.66, p <0.05). In conclusion, resynchronization pacing led to a significant increase in arterial blood pressure and was a useful adjunct to the treatment of acute postoperative heart failure in patients with AV and/or IV conduction delay.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0002-9149(01)01609-5 | DOI Listing |
Egypt Heart J
January 2025
Department of Cardiology, Hangzhou First People's Hospital, #261 Huansha Road, Hangzhou, 310000, Zhejiang Province, China.
Background: To investigate the optimization of leadless pacemaker placement and to assess its impact on heart synchronization and tricuspid regurgitation.
Results: A clinical trial was conducted involving 53 patients who underwent leadless pacemaker implantation at the Second Affiliated Hospital of Zhejiang University School of Medicine and Hangzhou First People's Hospital between March 2022 and February 2023. Implantation site localization was determined using the 18-segment method under RAO 30° imaging.
ACS Sens
January 2025
Jiangsu Provincial Key Laboratory of Advanced Robotics, School of Mechanical and Electric Engineering, Soochow University, Suzhou 215137, China.
Atrial fibrillation (AF) as one of the most common cardiovascular diseases has attracted great attention due to its high disability and mortality rate. Thus, a timely and effective recognition method for AF is of great importance for diagnosing and preventing it. Herein, we proposed a novel intelligent sensing and recognition system for AF which combined Traditional Chinese Medicine (TCM), flexible wearable electronic devices, and artificial intelligence.
View Article and Find Full Text PDFPLoS One
December 2024
Department of Radiology, Columbia University, New York, NY, United States of America.
Background: Imaging both electrical and mechanical cardiac function can better characterize cardiac disease and improve patient care. Currently, there is no noninvasive technique that can simultaneously image both electrical and mechanical function of the whole heart at the point of care. Here, our aim is to demonstrate that high volume-rate echocardiography can simultaneously map cardiac electromechanical activation and end-systolic cardiac strain of the whole heart in a single heartbeat.
View Article and Find Full Text PDFJACC Case Rep
November 2024
Division of Cardiovascular Medicine, Hillel Yaffe Medical Center, The Ruth and Bruce Rappaport Faculty of Medicine, Technion, Haifa, Israel.
We herein describe a case of successful atrioventricular synchrony at an 8-week follow-up in a patient who received a leadless pacemaker for recurrent right ventricular lead failures and had a pre-existing atrial transvenous pacemaker. Given the significant hemodynamic improvements, careful initial programming and adjustments during follow-up are needed.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!