We compared the biomechanical stability of 60 degrees and 90 degrees angles for insertion of screws for fixation of sagittal split ramus osteotomies (SSROs) in 10 sheep mandibles in vitro. After 5 mm advancements, the osteotomies were fixed with screws 2 mm in diameter inserted with a torque control screwdriver at either 60 degrees or 90 degrees to the long axis of bone, in a matched pair experimental design. All specimens were then loaded in a physiological manner and the load-displacement of the osteotomies was recorded. Data for resistance to movement were compared by a paired t -test. The mean (SD) resistance to movement for the 60 degrees and 90 degrees screw insertions was 63.4 (27.7) N/mm and 59 (22.3) N/mm respectively. There was no significant difference between the groups. This correlates with clinical findings.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1054/bjom.2000.0580 | DOI Listing |