Directed balloon-assisted guidewire access into intrahepatic ducts.

Gastrointest Endosc

Division of Gastroenterology, Washington University School of Medicine, St. Louis, Missouri 63110, USA.

Published: July 2001

Download full-text PDF

Source
http://dx.doi.org/10.1067/mge.2001.114957DOI Listing

Publication Analysis

Top Keywords

directed balloon-assisted
4
balloon-assisted guidewire
4
guidewire access
4
access intrahepatic
4
intrahepatic ducts
4
directed
1
guidewire
1
access
1
intrahepatic
1
ducts
1

Similar Publications

Endoscopic Management of Benign Pancreaticobiliary Disorders.

J Clin Med

January 2025

Division of Gastroenterology and Hepatology, Center for Digestive Health, Virginia Mason, Franciscan Health, Seattle, WA 98101, USA.

Endoscopic management of benign pancreaticobiliary disorders encompasses a range of procedures designed to address complications in gallstone disease, choledocholithiasis, and pancreatic disorders. Acute cholecystitis is typically treated with cholecystectomy or percutaneous drainage (PT-GBD), but for high-risk or future surgical candidates, alternative decompression methods, such as endoscopic transpapillary gallbladder drainage (ETP-GBD), and endoscopic ultrasound (EUS)-guided gallbladder drainage (EUS-GBD), are effective. PT-GBD is associated with significant discomfort as well as variable adverse event rates.

View Article and Find Full Text PDF

Background And Aim: The impact of different anti-thrombotic agents on patients with suspected small bowel bleeding (SSBB) who underwent balloon-assisted enteroscopy (DAE) is unclear. We aimed to examine the clinical effects and predictive factors of DAE based on the thromboembolic agents used.

Methods: We enrolled 399 patients with SSBB from a web-based DAE registry across 30 medical centers in South Korea.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the use of intraoperative neurophysiological monitoring (IONM) during surgeries for blood-blister-like aneurysms (BBA), which are complicated due to high risks of complications and death.
  • Researchers monitored patients using somatosensory and transcranial motor evoked potentials (SSEPs/tcMEPs) to assess neurological outcomes, revealing a low sensitivity (37.5%) but high specificity (100%) for detecting ischemic events during surgery.
  • Results indicate that while IONM can accurately identify healthy brain function, it has a high rate of false negatives, particularly in complex surgical procedures, highlighting the need for careful interpretation and further studies.
View Article and Find Full Text PDF
Article Synopsis
  • A rare case of spontaneous direct vertebral artery-external vertebral venous plexus (VA-EVVP) fistula was diagnosed in an 82-year-old woman without trauma history or neurological deficits, presenting with right hemianopsia.
  • Initial MRI suggested an old infarction and a dural arteriovenous fistula, but further imaging revealed a specific AV fistula at the C2 level.
  • The patient underwent successful coil embolization, resulting in complete obliteration of the fistula after follow-up, providing new insights into treating VA-EVVP fistulas.
View Article and Find Full Text PDF

Radiation dose analysis in interventional neuroradiology of unruptured aneurysm cases.

J Radiol Prot

September 2024

Department of Endovascular Neurosurgery, Toranomon Hospital, 2-2-2 Toranomon, Minato-ku, Tokyo 105-8470, Japan.

This study aimed to evaluate the radiation doses (peak skin dose (PSD) and bilateral lens dose) for each interventional neuroradiology procedure. A direct measurement system consisting of small radiophotoluminescence glass dosimeter chips and a dosimetry cap made of thin stretchable polyester was used for radiation dosimetry. The mean PSDs for each procedure were 1565 ± 590 mGy (simple technique coil embolization (STCE) cases), 1851 ± 825 mGy (balloon-assisted coil embolization (BACE) cases), 2583 ± 967 mGy (stent-assisted coil embolization (SACE) cases), 1690 ± 597 mGy (simple flow-diverter stenting (FDS) cases), and 2214 ± 726 mGy (FDS + coiling cases).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!