Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3145
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To evaluate the hemodynamic outcome of technically successful percutaneous transluminal renal artery angioplasty and stent placement (PTRAS) with duplex ultrasonography (US).
Materials And Methods: Eighteen patients who underwent PTRAS in 22 renal arteries were prospectively examined. All had abnormal preprocedural duplex US findings. Those who had significant renal artery stenosis (>70%) at angiography and underwent technically successful percutaneous interventions were enrolled. Standard intrarenal duplex US parameters (acceleration index [AI], acceleration time, waveform morphology grade, and resistive index) were compared before and after interventions.
Results: A significant AI increase occurred after PTRAS (9.02 m/sec(2) +/- 4.85 [SD]), as compared with before intervention (2.34 m/sec(2) +/- 2.03; P <.001). Acceleration time significantly decreased from 0.084 second +/- 0.049 to 0.032 second +/- 0.008 (P <.01). There was also a significant resistive index increase from 0.69 +/- 0.12 to 0.79 +/- 0.12 (P <.01). Abnormal waveform morphology (modified Halpern waveform grade 3-6) was present in 19 (86%) of 22 intrarenal arteries prior to intervention, as compared with one (5%) after PTRAS (P <.001). In the instance in which an abnormal waveform persisted after intervention, waveform morphology improved from grade 6 to grade 3, with a concomitant AI increase from 0.96 to 5.1 m/sec(2).
Conclusion: The findings suggest an important potential role for duplex US in noninvasive assessment of the immediate hemodynamic outcome and long-term follow-up of PTRAS.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1148/radiology.220.1.r01jl11168 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!