Background: Magnetic resonance imaging is often used to assess for disk displacement after manipulation, but limited information about the true incidence of iatrogenic herniations exists. To design a study that evaluates for a causal relationship, preliminary data must be obtained relating to the size of different types of disk displacement. The reliability of chiropractic radiologists in assessing disks and a comparison of different measuring devices should also be evaluated.

Objective: To identify average measurements for normal and displaced disks and to assess the reliability of measurements by chiropractic radiologists.

Study Design: Intraobserver and interobserver reliability study assessing disk displacement on magnetic resonance scans.

Methods: Three evaluators assessed the disks on 122 magnetic resonance scans from two imaging centers. Six categories were graded, and digitizer and ruler measurements were compared. Forty-four scans were reassessed for intraobserver agreement. Intraobserver and interobserver variations were measured with intraclass correlation coefficient and kappa statistical analysis. Measurement device correlation was assessed with Pearson's r.

Results: Clear size differences between different types of disk displacement were noted. Interexaminer measurement reliability was 0.78 to 0.84. Agreement concerning the presence of disk displacement was 85% (kappa = 0.68), and the classification of disk displacements was 76% (kappa = 0.60). Intraexaminer measurement reliability was 0.40 to 0.49. Intraexaminer agreement concerning the presence of disk displacement was 76% (kappa = 0.52), and the classification of disk displacements was 62% to 69% (kappa = 0.38 to 0.46). Normal versus bulged disk distinctions demonstrated the most disagreement. The ruler and digitizer correlation coefficient was 0.968.

Conclusions: Different disk types demonstrated distinct size averages. Interexaminer agreement was good concerning disk assessment and measurements. Intraexaminer agreement was lower than expected. A millimetric ruler is an acceptable alternative to digital measurement devices.

Download full-text PDF

Source
http://dx.doi.org/10.1067/mmt.2001.115266DOI Listing

Publication Analysis

Top Keywords

disk displacement
28
magnetic resonance
12
disk
11
types disk
8
intraobserver interobserver
8
correlation coefficient
8
measurement reliability
8
agreement concerning
8
concerning presence
8
presence disk
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!