Stereotactic guided laser-induced interstitial thermotherapy (SLITT) represents a minimal invasive method to produce necrosis in cerebral tumor tissue by local heating. The dose/response relationship relies on experimental studies and few clinical data performed in high field MR systems. A better understanding of the energy-dose/tissue response in human brain tumors is important to optimize this treatment modality. Twenty-four patients with gliomas were treated with SLITT, with a total of 30 laser procedures performed. Under local anesthesia 600 microns laser-fibers were inserted by stereotactic-guided technique into the center of the tumor. In a low field open MR system (0.2 T) the denaturation of the tumor using a neodymium YAG laser (1064 nm) was monitored by 3D-turbo FLASH T1-weighted sequences. Laser energy was applied in steps of 400 to 1200 Joules. Development of necrosis at a mean total energy dose of 2979 Joules could be monitored in all procedures. Two different thermal lesion architectures were observed. First signal changes were monitored after a mean of 1108 Joules and 1393 Joules, respectively. Mean max. total lesion size was 21.2 mm. The higher the total energy the larger was the thermolesion, but no linear relationship could be seen. Tumor tissue response showed no dependency on tumor grading. Monitoring of stereotactic guided laser-induced thermolesions in the low-power MR OPEN is feasible and safe. Although lesion size basically is energy dependent, it should be applied individually, since the thermal response in brain tumors varies due to different optical properties, even in the same tumor gradings.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-2001-13581DOI Listing

Publication Analysis

Top Keywords

stereotactic guided
12
guided laser-induced
12
laser-induced interstitial
8
interstitial thermotherapy
8
thermotherapy slitt
8
tumor tissue
8
brain tumors
8
total energy
8
lesion size
8
tumor
6

Similar Publications

Assessing Malignant Risk in B3 Breast Lesions: Clinical Insights and Implications.

J Clin Med

December 2024

Multidisciplinary Breast Centre, Dipartimento Scienze della Salute della Donna e del Bambino e di Sanità Pubblica, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy.

: B3 breast lesions, characterized by uncertain malignant potential, pose a significant challenge for clinicians. With the increasing use of preoperative biopsies, there is a need for careful management strategies, including watchful waiting, vacuum-assisted excision (VAE), and surgery. This study aims to assess the concordance between preoperative biopsy findings and postoperative histology, with a focus on evaluating the positive predictive value (PPV) for malignancy in B3 lesions.

View Article and Find Full Text PDF

Oligometastatic prostate cancer (OMPC) represents an intermediate state in the progression from localized disease to widespread metastasis when the radiographically significant sites are limited in number and location. With no clear consensus on a definition, its diagnostic significance and associated optimal therapeutic approach remain controversial, posing a significant challenge for clinicians. The current standard of care for metastatic disease is to start systemic therapy; however, active surveillance and targeted radiotherapy have become attractive options to mitigate the long-term effects of androgen deprivation therapy (ADT).

View Article and Find Full Text PDF

Purpose: To use imaging data from stereotactic MR-guided online adaptive radiotherapy (SMART) of ultracentral lung tumors (ULT) for development of a safe non-adaptive approach towards stereotactic body radiotherapy (SBRT) of ULT.

Patients And Methods: Analysis is based on 19 patients with ULT who received SMART (10 × 5.0-5.

View Article and Find Full Text PDF

Stereotactic systems have traditionally used Cartesian coordinate combined with linear algebraic mathematical models to navigate the brain. Previously, the development of a novel stereotactic system allowed for improved patient comfort, reduced size, and carried through a simplified interface for surgeons. The system was designed with a work envelope and trajectory range optimized for deep brain stimulation applications only.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!