Titanium mesh repair of the severely comminuted frontal sinus fracture.

Arch Otolaryngol Head Neck Surg

Department of Otolaryngology-Head & Neck Surgery, University of California Irvine College of Medicine, 101 The City Drive South, Bldg 25, Orange, CA 92868, USA.

Published: June 2001

Background: Severely comminuted frontal sinus fractures are difficult to contour and immobilize. Frequently, plates or wires are inadequate in fixating all fragments together, resulting in less than optimal outcomes. Advancements in the development of biomaterials have now made titanium mesh a new option for the repair of severely comminuted fractures.

Methods: Fourteen patients with severely comminuted frontal sinus fractures were treated with titanium mesh from 1994 to 1999. The fractures were reduced and immobilized using a simple algorithm: (1) Isolated anterior table fractures were repaired with reduced bony fragments attached to titanium mesh. (2) Anterior table fractures with nasofrontal duct involvement were repaired by sinus obliteration and anterior wall reconstruction with reduced bony fragments attached to titanium mesh. (3) Anterior and posterior table fractures with cerebrospinal fluid leak or displacement were treated with the cranialization of the sinus and anterior wall reconstruction with reduced bony fragments attached to titanium mesh.

Results: Of the 14 patients treated, 12 were available for postoperative evaluation. Parameters such as nasal function, cranial nerve V and VII function, cosmesis, and complications (hardware extrusions, sinusitis, meningitis, osteomyelitis, mucopyocele, brain abscess, pneumocephalus, and cerebrospinal fluid leak) were evaluated. All patients had good function of the superior division of cranial nerves V and VII. Two patients (16%) had minor wound infections, which resolved under treatment with antibiotics. All had excellent cosmetic results as measured by postreduction radiographs and personal and family perceptions of forehead contour.

Conclusion: Titanium mesh reconstruction of severely comminuted frontal sinus fractures has few complications while providing excellent forehead contour and cosmesis.

Download full-text PDF

Source
http://dx.doi.org/10.1001/archotol.127.6.665DOI Listing

Publication Analysis

Top Keywords

titanium mesh
24
severely comminuted
20
comminuted frontal
16
frontal sinus
16
sinus fractures
12
table fractures
12
reduced bony
12
bony fragments
12
fragments attached
12
attached titanium
12

Similar Publications

Intracranial Hypotension Mechanism and Implant Retention Procedure for Patients With Titanium Mesh Exposure.

Oper Neurosurg (Hagerstown)

January 2025

Department of Neurosurgery, Huashan Hospital, Shanghai Medical College, Fudan University, Shanghai, China.

Background And Objectives: The study aimed to investigate the potential pathogenesis and present an implant retention procedure for patients with titanium mesh exposure after cranioplasty.

Methods: The clinical data were obtained from 26 consecutive cases with titanium mesh exposure who underwent surgical treatment between 2018 and 2023. These patients' medical records, scalp photographs, operative notes, and outcomes were retrospectively analyzed.

View Article and Find Full Text PDF
Article Synopsis
  • Cage subsidence can negatively affect lumbar fusion procedures, with material selection (PEEK vs. 3D-Ti) influencing this issue; the study aims to compare their subsidence rates.
  • The systematic search reviewed 265 patients from three high-quality studies, focusing on cage subsidence and classified subsidence rates using a specific method.
  • Results indicated that 3D-Ti cages have a significantly lower rate of subsidence compared to PEEK cages, with less severe subsidence and better overall performance.
View Article and Find Full Text PDF

Background: Anterior cervical corpectomy and fusion (ACCF) is a standard surgical procedure for cervical spondylosis with spinal cord compression (CSWSCC), especially in patients with intensity on T2-weighted imaging high signal (T2WIHS). The titanium mesh cage (TMC) utilized in this procedure is essential in stabilizing the spine; however, the optimal slotting width of the TMC remains unclear.

Objective: This study aimed to investigate the impact of TMC slotting width on the clinical and radiological outcomes of ACCF in patients with spinal cord compression type cervical spondylosis with intensity on T2WIHS (CST2WIHS).

View Article and Find Full Text PDF

Surgical management of costal margin rupture associated with intercostal hernia: Evolution of techniques.

J Trauma Acute Care Surg

October 2024

From the Sheffield Teaching Hospitals NHS Foundation Trust (P.W., J.N.R., S.T., J.G.E.), Sheffield, England; Erasmus Medical Centre (M.M.E.W.), Rotterdam, The Netherlands; and University Hospital of Southampton NHS Foundation Trust (A.T.).

Introduction: Costal margin rupture (CMR) injuries in association with intercostal hernia (IH) are rare and symptomatic and provide a significant surgical challenge. Surgical failure rates up to 60% are reported, and optimal techniques are unclear. We have characterized these injuries and describe the evolution of our surgical management techniques.

View Article and Find Full Text PDF

Introduction And Importance: Growing skull fracture is one the rarest complication of skull fracture. They are identified mostly in infancy and children's, secondary to head trauma but there exist possibility of missed diagnosis in childhood and patient presenting in adulthood with delayed complications. Hence timely diagnosis and prompt management is mandatory.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!