Four mandibular screw-plate locking systems were studied in sheep. Three to four centimetres angular continuity resections of the mandible were performed and the defects bridged with pre-bent angular reconstruction plates fixed with four screws in the body part and three in the ramus. Each type was used four times. Clinical and radiological examinations were carried out 1 and 2 months later. All sheep were able to eat and ruminate normally throughout the postoperative period. Radiology revealed that 6/16 plates and 5/112 screws fractured during the follow-up period. In one type, no fracture occurred. Screw fracture was confined to just one reconstruction system. Six of 16 mandibles showed slight to moderate bone resorption under the plate. The results point to the internal shortcomings of the systems tested.

Download full-text PDF

Source
http://dx.doi.org/10.1054/ijom.2000.0037DOI Listing

Publication Analysis

Top Keywords

screw-plate locking
8
locking systems
8
clinical radiological
8
comparative study
4
study screw-plate
4
systems sheep
4
sheep clinical
4
radiological study
4
study mandibular
4
mandibular screw-plate
4

Similar Publications

Article Synopsis
  • Polyaxial locking systems are commonly utilized in surgeries for challenging cases, such as osteoporotic bones or complicated fractures, but they may decrease stiffness compared to standard designs.
  • A new plate design featuring narrow construction with asymmetric holes and polyaxial capabilities was tested against traditional narrow plates, using three settings with different screw orientations.
  • The results revealed that while polyaxial systems improve surgical placement flexibility, they incur a reduction in torsional strength; however, all groups maintained a strong screw-plate connection even under stress.
View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to evaluate the effectiveness of variable pitch locking screws in providing better interfragmentary and plate-bone compression compared to standard locking screws in cadaver bone, focusing on biomechanical stability.
  • Nine pairs of fresh-frozen cadaver specimens were tested for differences in compression forces and overall stability using both screw types under different loading conditions.
  • Results showed that variable pitch screws provided significantly greater interfragmentary and plate-bone compression, while no significant differences were found in the stability of constructs during cyclic loading or in 4-point bending tests.
View Article and Find Full Text PDF

The clavicle has various anatomic shapes unique to each individual. Additionally, with the increase in high-energy traumas such as sports injuries and traffic accidents, the patterns of fractures become complex and complicated. Thus, there is a need for a variety of shapes of locking compression plates (LCP) to accommodate different types of fractures and facilitate quicker rehabilitation.

View Article and Find Full Text PDF

In vitro biomechanical analysis of a locking self-compression screw model applied to Pauwels III and comminuted femoral neck fractures.

Injury

November 2023

Department of Orthopedics and Traumatology, Faculty of Medical Sciences, Universidade Estadual de Campinas (UNICAMP), Rua Vital Brasil, 80, Campinas 13083-888, SP, Brazil.

Femoral neck fractures (FNFs) affect the young adult population and are intimately related to high-energy trauma. Despite innovations in osteosynthesis materials, the rate of complications remains at 10%-59% in Pauwels type III (PIII) fractures. The authors thus propose a fixation model with a novel self-compression screw, comparing it to a sliding hip screw plate associated with a derotation screw in the fixation of a PIII fracture with posterior inferior comminution.

View Article and Find Full Text PDF

Biomechanical evaluation of variable angle locking systems. A micro-CT analysis.

J Orthop Trauma

October 2023

Department of General Orthopaedics, Musculoskeletal Oncology and Trauma Surgery, Poznań University of Medical Sciences, 61-545 Poznan, Poland.

Purpose: Formerly poor bone stock and periprosthetic fractures used to jeopardize monaxial constructs. Polyaxial locking screws have substantially supported those particular fixation constructs. However, those systems rely on complex alignment between the screw head and the plate hole.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!