Four mandibular screw-plate locking systems were studied in sheep. Three to four centimetres angular continuity resections of the mandible were performed and the defects bridged with pre-bent angular reconstruction plates fixed with four screws in the body part and three in the ramus. Each type was used four times. Clinical and radiological examinations were carried out 1 and 2 months later. All sheep were able to eat and ruminate normally throughout the postoperative period. Radiology revealed that 6/16 plates and 5/112 screws fractured during the follow-up period. In one type, no fracture occurred. Screw fracture was confined to just one reconstruction system. Six of 16 mandibles showed slight to moderate bone resorption under the plate. The results point to the internal shortcomings of the systems tested.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1054/ijom.2000.0037 | DOI Listing |
Bioengineering (Basel)
October 2024
Department of Mechanical Engineering, University of Las Palmas de Gran Canaria, 35017 Las Palmas de Gran Canaria, Spain.
J Orthop Trauma
October 2024
Department for Orthopaedics and Rehabilitation, Penn State College of Medicine, Hershey, PA.
Sci Rep
March 2024
Department of Orthopedic Surgery, College of Medicine, Soonchunhyang University Gumi Hospital, Gumi, 39371, Republic of Korea.
The clavicle has various anatomic shapes unique to each individual. Additionally, with the increase in high-energy traumas such as sports injuries and traffic accidents, the patterns of fractures become complex and complicated. Thus, there is a need for a variety of shapes of locking compression plates (LCP) to accommodate different types of fractures and facilitate quicker rehabilitation.
View Article and Find Full Text PDFInjury
November 2023
Department of Orthopedics and Traumatology, Faculty of Medical Sciences, Universidade Estadual de Campinas (UNICAMP), Rua Vital Brasil, 80, Campinas 13083-888, SP, Brazil.
Femoral neck fractures (FNFs) affect the young adult population and are intimately related to high-energy trauma. Despite innovations in osteosynthesis materials, the rate of complications remains at 10%-59% in Pauwels type III (PIII) fractures. The authors thus propose a fixation model with a novel self-compression screw, comparing it to a sliding hip screw plate associated with a derotation screw in the fixation of a PIII fracture with posterior inferior comminution.
View Article and Find Full Text PDFJ Orthop Trauma
October 2023
Department of General Orthopaedics, Musculoskeletal Oncology and Trauma Surgery, Poznań University of Medical Sciences, 61-545 Poznan, Poland.
Purpose: Formerly poor bone stock and periprosthetic fractures used to jeopardize monaxial constructs. Polyaxial locking screws have substantially supported those particular fixation constructs. However, those systems rely on complex alignment between the screw head and the plate hole.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!