Study Objective: To prospectively address the question whether the assessment of valvular hemodynamics and myocardial function during low-dose dobutamine infusion can guide decision making in patients with aortic stenosis and left ventricular (LV) dysfunction.
Patients And Measurements: Twenty-four patients with aortic stenosis and LV dysfunction (mean ejection fraction, 28%; New York Heart Association class, II to IV) were studied by dobutamine echocardiography assessing mean pressure gradient, aortic valve area, and aortic valve resistance. Patients were prospectively divided into severe and nonsevere aortic stenosis groups according to the response of the valve area to the augmentation of systolic flow. The clinical decision was considered to be concordant with the results of dobutamine echocardiography, when patients with severe aortic stenosis and preserved contractile function were referred by a specialist for aortic valve replacement and when patients with nonsevere aortic stenosis were not. Patients were observed for up to 3 years.
Results: All eight patients with severe aortic stenosis who were referred for surgery survived and had good cardiovascular outcomes, and six of eight patients who were not initially referred for surgery had poor outcomes, including heart failure and sudden cardiac death. The eight patients with nonsevere aortic stenosis did comparatively well without valve replacement. Cardiac death or pulmonary edema occurred in 4 of 16 patients (25%) when the clinical decision was concordant with the results of the dobutamine echocardiogram and occurred in 6 of 8 patients (75%) when the clinical decision was discordant (p = 0.019 [chi(2) test]).
Conclusion: Patients with aortic stenosis, LV dysfunction, and relatively low gradients have better outcomes when management decisions are based on the results of dobutamine echocardiograms. Those patients identified as having severe aortic stenosis and preserved contractile reserve by dobutamine echocardiography should undergo surgery, while patients identified as having nonsevere aortic stenosis can be managed conservatively.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1378/chest.119.6.1766 | DOI Listing |
Background: Valve-related haemolysis is a known complication following prosthetic valve surgery. Haemolysis after transcatheter aortic valve implantation (TAVI) has been reported in some studies, all of which were non-critical. Data related to haemolysis associated with new-generation balloon-expandable valve (BEV) are scarce.
View Article and Find Full Text PDFJ Am Coll Cardiol
January 2025
Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea. Electronic address:
J Am Coll Cardiol
January 2025
Sydney Medical School, The University of Sydney, Sydney, New South Wales, Australia; Royal North Shore Hospital, Sydney, New South Wales, Australia.
J Am Soc Echocardiogr
January 2025
Department of Cardiovascular Medicine, Mayo Clinic, Phoenix, Arizona, USA.
Background: Aortic stenosis (AS) is a complex condition with various hemodynamic subtypes, each with distinct clinical profiles and outcomes. This study aimed to assess the characteristics and outcomes of different AS phenotypes based on flow and gradient patterns.
Methods: In this retrospective cohort study, we included 930 patients who underwent transcatheter aortic valve replacement (TAVR) for severe symptomatic AS at Mayo Clinic sites from 2012-2017.
Int J Numer Method Biomed Eng
January 2025
Department of Mathematics, University of Trento, Trento, Italy.
The main objectives of this work are to validate a 1D-0D unsteady solver with a distributed stenosis model for the patient-specific estimation of resting haemodynamic indices and to assess the sensitivity of instantaneous wave-free ratio (iFR) predictions to uncertainties in input parameters. We considered 52 patients with stable coronary artery disease, for which 81 invasive iFR measurements were available. We validated the performance of our solver compared to 3D steady-state and transient results and invasive measurements.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!