Objectives: To assess the incidence of complications of fluoroscopically guided caudal epidural injections.

Design: A retrospective cohort design study in which chart review was performed on patients, who presented with radiculopathy and received fluoroscopically guided caudal epidural steroid injections. All injections were performed consecutively over a 12-mo period. An independent observer reviewed medical charts, which included a 24-hr post procedure telephone call by an ambulatory surgery center nurse, who asked a standardized questionnaire about complications after the injections. Physician follow-up office notes 1 to 3 wk after injection along with epidurograms were reviewed.

Results: The charts of 139 patients, who received 257 injections, were reviewed. Complications per injection included 12 episodes of insomnia the night of the injection (4.7%), 9 transient nonpositional headaches that resolved within 24 hr (3.5%), 8 increased back pain (3.1%), 6 facial flushing (2.3%), 2 vasovagal reactions (0.8%), 2 episodes of nausea (0.8%), and 1 increased leg pain (0.4%). No dural punctures occurred.

Conclusions: No major complications occurred. The incidence of minor complications was 15.6% per injection. All reactions resolved without morbidity and no patient required hospitalization.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00002060-200106000-00005DOI Listing

Publication Analysis

Top Keywords

fluoroscopically guided
12
guided caudal
12
caudal epidural
12
complications fluoroscopically
8
complications
6
injections
5
epidural injections
4
injections objectives
4
objectives assess
4
assess incidence
4

Similar Publications

Purpose: The objective of this study was to explore the feasibility of using the TianJi Robot system for navigated needle positioning in the PCNL procedure in vitro.

Methods: A pig kidney with a segment of ureter was selected as the in vitro organ model. Iodine contrast agent was infused into the renal pelvis to dilate the renal pelvis and calyx to establish the in vitro hydronephrosis model.

View Article and Find Full Text PDF

3D-printed (3DP) drill guides have demonstrated significant potential to accurately guide pedicle screw insertion in spinal surgery. However, their role in the upper cervical spine is not well established. This review aimed to compare the efficacy and safety of 3DP drill guides to the conventional fluoroscopic-guided free-hand technique for pedicle screw insertion in the upper cervical spine.

View Article and Find Full Text PDF

Objective: To determine the feasibility, yield, and safety of fluoroscopic-guided aspiration of the acutely dislocated total hip arthroplasty (AD-THA).

Materials And Methods: IRB-approved, retrospective review of fluoroscopic-guided aspirations of AD-THA (January 2005-December 2023) was performed. Data from electronic charts and fluoroscopy images/reports were obtained.

View Article and Find Full Text PDF

Background: Femoroacetabular impingement (FAI) is a well-recognized cause of hip pain in adults. The hip-spine relationship between the femur, pelvis, and lumbosacral spine has garnered recent attention in hip arthroplasty. However, the hip-spine relationship has not been well described in patients with FAI.

View Article and Find Full Text PDF

Background: The pelvis is one of the most common areas for metastatic bone disease. We recently described the use of a minimally invasive percutaneous screw fixation of metastatic non-periacetabular pelvic lesions, with excellent results.

Description: The procedure can be completed in a standard operating theater without the need for special instruments.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!