A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of the capacity of the SCGE assay to assess the genotoxicity of biomaterials. | LitMetric

The comet test or SCGE assay, which is already widely used in other areas, has never been used to evaluate the mutagenic potential of medical biomaterials in the final form. The purpose of our study was thus to assess the comet test as a means of assessing the genotoxic potential of finished medical biomaterials. We used silicone elastomers with increasing concentrations of 4-nitroquinoline oxide, a genotoxic agent. Hydrogen peroxide was used as the positive control, and tissue culture polystyrene as the negative control. In our study, the comet test did not detect a significant difference in genotoxicity between the pure elastomer and the same elastomer containing 0.01 mg/ml 4-nitroquinoline oxide, but did detect a significant difference between two elastomers containing 0.01 and 0.3 mg/ml of 4-nitroquinoline oxide, respectively. Since, the surface properties of the samples were identical, only the chemical composition may have caused significant differences in mutagenicity. Whatever the cause of the genotoxicity detected by the SCGE assay, testing finished biomaterials using the comet assay makes it possible to evaluate interactions between biomaterials and living tissues that are much closer to actual application conditions.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0142-9612(00)00351-3DOI Listing

Publication Analysis

Top Keywords

scge assay
12
comet test
12
4-nitroquinoline oxide
12
biomaterials comet
8
medical biomaterials
8
detect difference
8
001 mg/ml
8
mg/ml 4-nitroquinoline
8
biomaterials
5
evaluation capacity
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!