This study investigates the use of [(99m)Tc] liposomes for the detection of sentinel lymph nodes. A variety of [(99m)Tc] liposome formulations were compared with common lymphoscintigraphic agents including [(99m)Tc] regular-sulfur colloid (SC), [(99m)Tc] 0.22 microfiltered-SC, [(99m)Tc] reduced heating time 0.22 microfiltered-SC, and [(99m)Tc] human serum albumin (HSA) in rabbits. Images were acquired for the first 60 minutes and at 24 hours, followed by tissue biodistribution study. All agents except [(99m)Tc] regular SC demonstrated good migration from the injection site. Agents were retained in the popliteal node at 24 hours to varying degrees as follows: both [(99m)Tc] filtered SC preparations > [(99m)Tc] regular SC > [(99m)Tc] liposomes > [(99m)Tc] HSA. [(99m)Tc] liposome imaging can be used to develop novel liposome compositions with improved lymph node diagnostic and drug delivery characteristics.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0969-8051(01)00198-6DOI Listing

Publication Analysis

Top Keywords

[99mtc]
14
[99mtc] liposomes
12
lymphoscintigraphic agents
8
colloid [99mtc]
8
[99mtc] human
8
human serum
8
serum albumin
8
[99mtc] liposome
8
022 microfiltered-sc
8
microfiltered-sc [99mtc]
8

Similar Publications

Lack of effect of renal function on uptake of 99mTc-sestamibi in renal masses.

Nucl Med Commun

January 2025

Molecular Imaging and Therapeutics, Department of Radiology, University of North Carolina, Chapel Hill, North Carolina.

Objective: The appropriate clinical management of indeterminate small renal masses can be improved based on accurate risk stratification. This study aimed to investigate the impact of renal function on the uptake of technetium-99m (99mTc)-sestamibi, a widely available imaging agent that can be utilized to identify oncocytomas and other benign/indolent renal masses.

Methods: A retrospective cohort study was conducted, involving 100 consecutive patients who underwent 99mTc-sestamibi single-photon emission computed tomography/computed tomography.

View Article and Find Full Text PDF

Parathyroid Adenoma at the Parapharyngeal Space Detected on 99mTc-Sestamibi SPECT/CT.

Clin Nucl Med

January 2025

From the Nuclear Medicine Unit, Department of Diagnostic and Interventional Radiology, Queen Elizabeth Hospital, Hong Kong.

A 77-year-old woman was diagnosed with primary hyperparathyroidism, and initial cervical ultrasonography found no parathyroid lesion, and she was referred to the nuclear medicine unit for dual-phase 99mTc-sestamibi (MIBI) scan. The scintigraphy unveiled heterogeneous uptake patterns across bilateral thyroid lobes, corresponding to the thyroid nodules, alongside a marked focal uptake with delayed tracer washout in the right oral region. The SPECT/CT pinpointed a MIBI-avid nodule within the right parapharyngeal space, indicative of parathyroid ectopia.

View Article and Find Full Text PDF

The current study investigated the geometry, design and solid angle impacts on full energy peak efficiency (FEPE) of NaI(Tl) detectors for a line source. A line source is fabricated using 99mTc solution filled in a borosilicate glass tube of inner diameter 3 mm, tube wall thickness 2.5 mm and length 12.

View Article and Find Full Text PDF

Assessment of the interobserver and the intraobserver reproducibility for the detection of renal cortical defects in adults and children using [99mTc]Tc-MAG3.

Q J Nucl Med Mol Imaging

January 2025

Section of Nuclear Medicine and Diagnostic Imaging, International Atomic Energy Agency, Vienna, Austria.

Background: One can assess cortical defects on the early images of [99mTc]Tc-MAG3 renography. We aimed to assess interobserver and intraobserver reproducibility for detecting renal cortical defects using [99mTc]Tc-MAG3 for adults and children; identify causes for poor inter- and intraobserver reproducibility and to assess the effect of the kidney to background ratio (KTBR) on reproducibility.

Methods: One hundred adult and 200 pediatric renograms were included.

View Article and Find Full Text PDF

To investigate the potential of activated carbon from palm kernel shell waste for Tc-radiolabeled nanocarbon aerosol, a new production technology for carbon-based Tc-radioaerosol from such a waste was developed. Treated-palm shell charcoal (t-PSC) was prepared by hydrothermal method to increase the surface area, followed by Tc radiolabelling optimization. The optimal Tc radiolabeling conditions resulted in an adsorption capacity of 21.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!