The present study reports a novel method for the separation of the high-molecular-weight anionic polysaccharides, iota, kappa, and lambda carrageenans, in capillary electrophoresis (CE). Carrageenan samples are first derivatised with 9-aminopyrene-1,4,6-trisulfonic acid (APTS), separated in an ammonium acetate background electrolyte (BGE) and detected with laser-induced fluorescence (LIF). The effects of changes of instrumental parameters (temperature, injection mode, field strength) and the composition of the BGE (concentration and pH) are reported, and are explained in terms of the physical chemistry of the BGE and the biopolymers. Optimal separation conditions for kappa, iota, and lambda carrageenans, including an APTS internal standard, were found in a polyvinyl alcohol coated capillary with an ammonium acetate BGE of low concentration (25 mM) and moderate pH (8.0). This BGE gave the best reproducibility in tests on iota/kappa mixtures, with relative standard deviations (RSDs) in migration times and normalised peak areas (relative to the APTS internal standard) of less than 0.1% and 1%, respectively. Using this BGE at 50 degrees C and a voltage of 30 kV, all three carrageenan subtypes were separated in a run time of 3 min.

Download full-text PDF

Source
http://dx.doi.org/10.1002/1522-2683(200105)22:8<1460::AID-ELPS1460>3.0.CO;2-0DOI Listing

Publication Analysis

Top Keywords

capillary electrophoresis
8
lambda carrageenans
8
ammonium acetate
8
apts internal
8
internal standard
8
bge
6
separation iota-
4
iota- kappa
4
kappa lambda-carrageenans
4
lambda-carrageenans capillary
4

Similar Publications

Capillary Electrophoresis-Mass Spectrometry for Top-Down Proteomics.

Annu Rev Anal Chem (Palo Alto Calif)

January 2025

Department of Chemistry, Michigan State University, East Lansing, Michigan, USA; email:

Mass spectrometry (MS)-based top-down proteomics (TDP) characterizes proteoforms in cells, tissues, and biological fluids (e.g., human plasma) to better our understanding of protein function and to discover new protein biomarkers for disease diagnosis and therapeutic development.

View Article and Find Full Text PDF

Serum HDL and their subfractions are impaired in multisystem inflammatory syndrome in children (MIS-C).

J Transl Med

January 2025

Dipartimento di Pediatria Generale e d'Urgenza, AORN Santobono-Pausilipon, Naples, Italy.

Background: Multisystem inflammatory syndrome in children (MIS-C) is a severe post-COVID condition due to a delayed hyperimmune response to SARS-CoV-2. High-density lipoproteins (HDL) are pivotal players in inflammatory and immune modulation through the remodeling of their subfractions.

Methods: This study aimed to evaluate serum levels of cholesterol, HDL, and HDL subfractions (HDL-SUB) to define their role in the pathogenesis of MIS-C and their potential use as biomarkers of this condition.

View Article and Find Full Text PDF

The development and validation of an accurate, selective, and eco-friendly capillary zone electrophoretic detection (CZE) method has been presented for concurrent measurement of inorganic and organic anions including chloride, sulfate, formic acid, citric acid, acetic acid, phosphate, and glutamic acid in Human Milk Oligosaccharides (HMOs) for the first time. An electrolyte composed of an aqueous solution of benzoic acid, 16.38 mM; l-histidine, 24.

View Article and Find Full Text PDF

Genotype-phenotype correlation and potential genetic risk in the compound heterozygosity for unstable hemoglobins (UHbs) and α-thalassemia were discussed. Capillary electrophoresis and gene sequencing helped to establish the diagnosis. Hematological analysis showed the following findings: MCV 80.

View Article and Find Full Text PDF

Advancements in food technology have increased the need for thorough analysis to ensure food safety, quality, and compliance with regulatory requirements. Capillary electrophoresis-mass spectrometry (CE-MS) has emerged as a powerful tool in food analysis due to its high separation efficiency, low sample consumption, and ability to handle complex matrices. However, challenges such as the use of volatile running buffers and maintaining the stability of the electrical circuit connecting the CE and MS systems have been addressed through advancements in interface designs, such as sheathless systems and optimized sheath-liquid compositions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!