Identification of gunshot residue: a critical review.

Forensic Sci Int

Head, Gunshot Residue Analysis Laboratory, Direzione Centrale Polizia Criminale, Servizio Polizia Scientifica, Viale dell'Aeronautica 7, 00144 Rome, Italy.

Published: June 2001

A review of the scientific papers published on inorganic gunshot residue (GSR) analysis permits to study how the particle analysis has shown its capability in detection and identification of gunshot residue. The scanning electron microscope can be the most powerful tool for forensic scientists to determine the proximity to a discharging firearm and/or the contact with a surface exposed to GSR. Particle analysis can identify individual gunshot residue particles through both morphological and elemental characteristics. When particles are detected on the collected sample, the analytical results can be interpreted following rules of a formal general interpretative system, to determine whether they come from the explosion of a primer or from other possible sources. The particles on the sample are compared with an abstract idea of "unique" GSR particle produced by the sole source of the explosion of a primer. "Uniqueness" is not the only problem related to GSR detection and identification for a forensic scientist. With "not-unique" particles interpretation of results is extremely important. The evidential strength of "not-unique" particles can increase with a more fruitful interpretative framework based on Bayes rule. For the assessment of the value of a GSR in linking a suspect and a crime, it is important to compare two hypothesis: the first can be that of the evidence if the suspect has been shooting in a specific situation, the second that of the evidence if the suspect was not involved in this shooting. This case specific or case-by-case approach is closer to what the court is interested in. The authors consider that a "case-by-case" approach should be followed whenever possible. Research of models and data such as those developed in other trace evidence material (fibres, glass, etc.) using a Bayesian approach is suggested in the interpretation of GSR.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0379-0738(00)00428-xDOI Listing

Publication Analysis

Top Keywords

gunshot residue
16
identification gunshot
8
particle analysis
8
detection identification
8
gsr particle
8
explosion primer
8
"not-unique" particles
8
evidence suspect
8
gsr
6
particles
5

Similar Publications

Firearm-related scenarios can be highly complex, involving multiple shooters, firearms, types of ammunition, victims, and various impact zones. Obtaining the maximum amount of information to connect each piece of the puzzle is crucial for resolving these cases. Currently, new tools are being developed in the forensic field that facilitate both fieldwork and laboratory analysis, enabling the estimation of trajectories, identification of shooters, and more.

View Article and Find Full Text PDF

Unlabelled: In forensic laboratories, analytical investigations of gunshot residues (GSRs) are usually conducted by scanning electron microscopy (SEM) in combination with energy dispersive X-ray microanalysis. If GSRs are covered with bloodstains, SEM cannot detect them. In this study, an inductively coupled plasma mass spectrometry method is proposed to solve this problem.

View Article and Find Full Text PDF

In modern analytical chemistry, one of the primary goals is to develop miniaturized, easy-to-use sensing tools, particularly those with multitasking capabilities. In this work, we designed a mini-voltammetric cell that integrates a modified Au microelectrode (Au/Au NPs as the working electrode) and an Ag/AgCl reference electrode installed within a micropipette tip. This combined tool not only enables portable and on-site microvolume sampling─requiring only a microvolume (around 20-40 μL) or a single droplet─but also facilitates direct micro-electroanalysis in a short time.

View Article and Find Full Text PDF

In firearm forensic investigations, detecting gunshot residue (GSR) is crucial for linking firearms to suspects and determining firing distance for forensic reconstruction. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-ToF-MS) is emerging as a versatile and promising technological platform for fingerprint analysis. The capability of functionalized particles as an advanced dusting powder for visualizing latent fingerprints is widely recognized.

View Article and Find Full Text PDF

Identification of gunshot entry wounds using hyperdense rim sign on post-mortem computed tomography.

Int J Legal Med

October 2024

Service de Radiologie, GHU Paris Psychiatrie Et Neurosciences, Site Sainte-Anne, 1, Rue Cabanis, 75014, Paris, France.

Article Synopsis
  • Post-mortem computed tomography (PMCT) is a valuable technique in forensic medicine for assessing head gunshot injuries, particularly through signs like vault bevelling to help identify entry and exit wounds.
  • A new study tested the cutaneous hyperdense rim sign, which could indicate entry wounds, showing high specificity (97%) but moderate sensitivity (63%) when analyzed in 64 cases of gunshot wounds.
  • The research found a significant correlation between the hyperdense rim sign and the presence of powder residues or bullet wipe, supporting its potential as an effective tool for determining gunshot entry wounds alongside other forensic methods.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!