We report a long-term review of 41 acetabular reconstructions using impacted morsellized bone grafts and a cemented total hip arthroplasty (THA) in patients younger than 50 (22-49; average 38) years. Reconstruction was performed in 23 primary THA (19 patients) and 18 revision THA (17 patients). 3 patients were lost to follow-up and 3 (4 hips) died within 10 years of surgery; none had a revision. Thus, 34 hips (30 patients) were reviewed with an average follow-up of 13 (10-18) years. In 2 hips, a revision was performed for aseptic loosening of the acetabular component 7 and 11 years after surgery. One additional cup was revised after 12 years during a femoral stem revision due to wear and matching problems, but was well fixed. The survival rate of the acetabular reconstruction technique was 94% (95% CI: 90-98%).

Download full-text PDF

Source
http://dx.doi.org/10.1080/000164701317323354DOI Listing

Publication Analysis

Top Keywords

tha patients
12
acetabular reconstruction
8
impacted morsellized
8
morsellized bone
8
bone grafts
8
patients younger
8
cemented total
8
total hip
8
years surgery
8
patients
6

Similar Publications

Efficacy of small-diameter core decompression with platelet-rich plasma in early osteonecrosis of the femoral head: a retrospective study.

BMC Musculoskelet Disord

January 2025

Department of Orthopedics and Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, People's Republic of China.

Background: Osteonecrosis of the femoral head (ONFH) is a challenging condition, primarily affecting young and middle-aged individuals, which results in hip dysfunction and, ultimately, femoral head collapse. However, the comparative effectiveness of joint-preserving procedures, particularly in the early stages of ONFH (ARCO stage I or II), remains inconclusive. This study aims to evaluate the efficacy of a novel technique called small-diameter core decompression (CD) combined with platelet-rich plasma (PRP), for the treatment of early-stage ONFH.

View Article and Find Full Text PDF

Perspectives surrounding robotic total hip arthroplasty: a cross-sectional analysis using natural language processing.

Can J Surg

January 2025

From the Faculty of Medicine, Université de Montréal, Montréal, Que. (Levett); the Department of Neurology and Neurosurgery, McGill University, Montréal, Que. (Elkaim); the Department of Orthopaedic Surgery, McGill University, Jewish General Hospital, Montréal, Que. (Zukor, Huk, Antoniou)

Background: Robotic technology has been used in total hip arthroplasty (THA) for several years. Despite the advances in this field, perspectives surrounding robotic THA are not fully understood. This study aimed to characterize the landscape of robotic THA on social media.

View Article and Find Full Text PDF

Introduction: For total hip arthroplasty (THA) to be successful, surgeons need to make several decisions ranging from implant choice to impaction force. It is unclear, however, whether and how bone quality affects surgeon's decision-making and how surgeons evaluate bone quality.

Objectives: This inductive/deductive qualitative hybrid study aims to explore the impact of bone quality on the decision-making of surgeons performing elective primary THA.

View Article and Find Full Text PDF

Purpose: Studies evaluating the long-term survival rate, patient satisfaction, and conversion to total hip arthroplasty (THA) are limited. The aim of this study was to evaluate satisfaction and hip survival at a minimum 10-year follow-up in patients following hip arthroscopy for femoroacetabular impingement syndrome (FAIS).

Methods: A total of 164 patients underwent hip arthroscopy for FAIS between 2007 and 2012; of these, 76 (49 men and 27 women; mean age, 40.

View Article and Find Full Text PDF

Aseptic loosening (AL) of artificial hip joints is the most common complication following hip replacement surgery. A total of eight patients diagnosed with AL following total hip arthroplasty (THA) undergoing total hip replacement and eight control patients diagnosed with avascular necrosis of femoral head (ANFH) or femoral neck fracture undergoing THA were enrolled. The samples of the AL group were from synovial tissue surrounding the lining/head/neck of the prosthesis, and the samples of the control group were from the synovium in the joint cavity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!