Anion gap (AG) is a calculated value commonly used in clinical practice. It approximates the difference between the concentration of unmeasured anions (UA) and unmeasured cations (UC) in serum. At present, the reference range of anion gap has been lowered from 8-16 to 3-11 mmol/l because of the changes in technique for measuring electrolyte. However, clinicians and textbooks still refer and use the old reference value of 8-16 mmol/l. This may lead to misinterpretation of the value of anion gap. Our study updated the value of anion gap in clinical diagnosis and laboratory evaluation. Criteria for using anion gap were also suggested. We analyzed serum electrolyte using the Beckman Synchron CX5. The anion gap was calculated from the formula: [Na(+)-(Cl(-)+HCO(3)(-))]. We estimated the reference range using the non-parametric percentile estimation method. The reference range of anion gap obtained from 124 healthy volunteers was 5-12 mmol/l, which was low and confirmed the reports from other studies (3-11 mmol/l) using ion-selective electrode. From the retrospective study on the 6868 sets of serum electrolyte among hospitalized patients, we found the incidences of normal, increased, and decreased anion gaps were 59.5%, 37.6%, and 2.9%, respectively. The mean and central 90% range of increased anion gap were 16 and 13-20 mmol/l, which was lower than those reported in previous study (25 and 19-28 mmol/l). Anion gap exceeding 24 mmol/l was rare. The mean and central 90% range of decreased anion gap were 3 and 2-4 mmol/l, which were lower than those reported in previous study (6 and 3-8 mmol/l). The value of less than 2 mmol/l was rare. The most common causes of increased anion gap (hypertensive disease, chronic renal failure, malignant neoplasms, diabetes mellitus and heart diseases) and decreased anion gap (liver cirrhosis and nephrotic syndrome) in this study were similar to those in previous studies. We found two cases of IgG multiple myeloma with anion gap of 2 mmol/l. In conclusion, clinicians and laboratorians can use the anion gap as clue in quality control. They can check the incidences of increased and decreased anion gap. If one finds high incidence of increased anion gap (>24 mmol/l) or decreased anion gap (<2 mmol/l), one should check the quality control of electrolyte and whether the patients were hypoalbuminemia or hyperglobulinemia. An anion gap exceeding 24 mmol/l will suggest the presence of metabolic acidosis. It is very rare to find anion gap with the negative sign.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0009-8981(01)00459-4 | DOI Listing |
ChemSusChem
January 2025
Indian Institute of Technology Ropar, Chemistry, Nangal Road, 140001, Rupnagar, INDIA.
Photocatalytic conversion of CO2 into value-added chemicals offers a propitious alternative to traditional thermal methods, contributing to environmental remediation and energy sustainability. In this respect, covalent organic frameworks (COFs), are crystalline porous materials showcasing remarkable efficacy in CO2 fixation facilitated by visible light owing to their excellent photochemical properties. Herein, we employed Lewis acidic Zn(II) anchored pyrene-based COF (Zn(II)@Pybp-COF) to facilitate the photocatalytic CO2 utilization and transformation to 2-oxazolidinones.
View Article and Find Full Text PDFJ Chem Theory Comput
January 2025
Institute for Computational Physics, University of Stuttgart, Allmandring 3, Stuttgart 70569, Germany.
The constant-pH Monte Carlo method is a popular algorithm to study acid-base equilibria in coarse-grained simulations of charge regulating soft matter systems including weak polyelectrolytes and proteins. However, the method suffers from systematic errors in simulations with explicit ions, which lead to a symmetry-breaking between chemically equivalent implementations of the acid-base equilibrium. Here, we show that this artifact of the algorithm can be corrected a-posteriori by simply shifting the pH-scale.
View Article and Find Full Text PDFBMC Cardiovasc Disord
January 2025
Department of Cardiovascular Diseases, The Second Affiliated Hospital of Anhui Medical University, 678 Furong Road, Hefei, 230601, Anhui, China.
Background: Compared to the conventional anion gap, the albumin-corrected anion gap (ACAG) offers a more precise measure of acid-base imbalance, providing superior prognostic insight. However, the prognostic relevance of ACAG in individuals of atrial fibrillation (AF) remains insufficiently explored. This research seeks to evaluate the correlation between ACAG levels and mortality risk in individuals with AF.
View Article and Find Full Text PDFTher Adv Respir Dis
January 2025
Department of Respiratory and Critical Care Medicine, The First Affiliated Hospital of Chongqing Medical University, No. 1 Youyi Road, Yuzhong, Chongqing 400016, China.
Background: The relationship between albumin-corrected anion gap (ACAG) and in-hospital mortality in critically ill patients with COPD remains unclear.
Objective: This study investigated the association between ACAG levels and the risk of in-hospital mortality in critically ill patients with COPD.
Design: A retrospective cohort study.
Sci Rep
January 2025
Emergency Medicine Laboratory and the Department of Emergency, West China Hospital, Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China.
To develop and evaluate a predictive model for intensive care unit (ICU) admission among patients with acute sedative-hypnotic overdose. We conducted a retrospective analysis of patients admitted to the emergency department of West China Hospital, Sichuan University, between October 11, 2009, and December 31, 2023. Patients were divided into ICU and non-ICU groups based on admission criteria including the need for blood purification therapy, organ support therapy (ventilatory support, vasoactive drugs, renal replacement therapy, artificial liver), or post-cardiopulmonary resuscitation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!