Long-term follow-up of severely atrophic edentulous mandibles reconstructed with short Brånemark implants.

Clin Implant Dent Relat Res

Brånemark Clinic, Public Dental Health Service, and Faculty of Odontology, Göteborg University, Sweden.

Published: June 2001

Background: Oral implant treatment (Brånemark System) of edentulous mandibles has been presented in numerous studies. However, with regard to the severely atrophic lower jaw, no long-term follow-up studies with solely short implants are available.

Purpose: The purpose of the present investigation was to retrospectively follow the long-term treatment outcome of patients with severely resorbed edentulous mandibles being subjected to oral implant placement with short (6-7 mm) Brånemark implants.

Materials And Methods: A total of 247 standard (7 mm long, Ø 3.75 mm) and 13 wide (6 mm long, Ø 5 mm) implants were inserted in 49 patients, all of whom exhibited severe resorption of edentate mandibles. Fixed implant-supported prostheses were manufactured for 45 patients, whereas 4 patients received overdentures. The patients were followed for a mean period of 8 years (range, 1-14 yr).

Results: Seventeen implants failed during the study period (cumulative implant survival rate 95.5% at 5-yr and 92.3% at 10-yr follow-up). Implant-supported constructions were worn continuously throughout the investigation by all study subjects. Marginal bone loss, measured after 1, 5, and 10 years of function, concurred with studies of Brånemark implants placed in more voluminous mandibles. No major clinical or construction complications occurred in the followed patients.

Conclusions: The outcome of the present study showed that placement of short Brånemark implants without the use of bone grafting procedures for reconstruction of severely atrophic edentulous mandibles is a highly predictable treatment procedure.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1708-8208.2000.tb00116.xDOI Listing

Publication Analysis

Top Keywords

edentulous mandibles
16
severely atrophic
12
brånemark implants
12
long-term follow-up
8
atrophic edentulous
8
short brånemark
8
oral implant
8
placement short
8
mandibles
6
implants
6

Similar Publications

Background: Worn dentition is a common problem encountered by most people in the last decade. Rehabilitation of a full mouth needs individual attention and proper treatment planning, which is very challenging for partial edentulous cases where bilateral teeth are missing and collapsed vertical dimension leaves inadequate restorative space. Treatment of these cases is complex and needs to apply standard principles while designing and fabricating prostheses.

View Article and Find Full Text PDF

The influence of prosthetic treatments and implant-supported prostheses on posterior mandibular ridge atrophy: a retrospective cohort study.

BMC Oral Health

January 2025

Division of Restorative Dentistry, Periodontology and Prosthodontics, Department of Dental Medicine and Oral Health, Medical University of Graz, Billrothgasse 4, Graz, 8010, Austria.

Aims: Bone preservation is a requirement for long-term stability of dental prostheses, which is all the more important in the posterior mandible, given the particular challenges these areas pose to prosthetic treatment. The objective was to investigate the implications of different prostheses on the atrophy of posterior alveolar bone after tooth loss.

Materials And Methods: A total of 457 treatment cases were retrieved from the medical documentation and information network.

View Article and Find Full Text PDF

Background: The continuous development in digital prosthodontics allowed the customization of attachments and retentive inserts which offers an easy and cheap solution for regular maintenance of locator overdentures during daily practice. The present study compared the change in retention values of the fully digitally manufactured custom-made locator attachment retentive insert with the ready-made ones after insertion, removal, and masticatory cycles.

Methods: A complete denture was constructed over a mandibular edentulous epoxy model.

View Article and Find Full Text PDF

Sandblasting and acid etching are common procedures used to treat implant surfaces, enhancing osseointegration and improving clinical success rates. This clinical study aimed to evaluate the long-term outcomes of sandblasted and acid-etched implants. A total of 303 implants were placed in 114 partially and totally edentulous patients using a two-stage surgical technique and an early loading protocol (6-8 weeks).

View Article and Find Full Text PDF

Objective: This study aimed to evaluate the clinical performance (degree of trueness) of a novel scan body "tooth-modified Scan body" (TMSB)& conventional scan body (CSB) in implant-supported full arch screw retained cases.

Methods: Seven edentulous arches (two maxillae, five mandibles) in 6 patients were rehabilitated with monolithic zirconia screw-retained implant prostheses supported by 4 (n = 1) and 5 implants (n = 6) for a total amount of 34 implants. Implant locations were scanned by intra-oral scanner (IOS) using two types of scan bodies, conventional scan bodies (CSB) in group (1) and tooth-modified scan bodies (TMSB) in group (2).

View Article and Find Full Text PDF