Optimization of scantiming in abdominal breathhold contrast-enhanced MRA: an empirical guideline.

Magn Reson Imaging

Department of Radiology, University Hospital Groningen, Hanzeplein 1, Groningen 9713 GZ, the Netherlands.

Published: February 2001

The objective of this study to determine a suitable scan timing scheme in contrast enhanced MRA for the depiction of the arterial, the portal and the systemic venous system in the abdomen with maximum signal intensity in healthy subjects and in patients with cirrhosis. The signal intensity in the aorta, hepatic artery, portal vein, left renal vein and the supra- and infrarenal IVC were measured in 40 consecutive orthotopic liver transplantation candidates with cirrhosis and 20 healthy renal donors in a bolus triggered arterial scan and after 30, 60, 90 and 150 s respectively. The aorta and hepatic artery showed the highest signal intensity on the arterial scan. The portal and left renal vein showed the highest signal intensity after 30 s, the suprarenal IVC after 60 s and the infrarenal IVC after 90 s. No significant differences were found between healthy subjects and patients with cirrhosis. The arterial, portal and systemic venous system in the abdomen can be visualized selectively with maximum signal intensity by proper timing of the scans, hereby reducing redundant scans. Scanning at just the right time to achieve optimal vessel opacification can be promoted by using data from this study. The proposed scan scheme is suitable for subjects with and without cirrhosis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0730-725x(01)00297-1DOI Listing

Publication Analysis

Top Keywords

signal intensity
20
arterial portal
8
portal systemic
8
systemic venous
8
venous system
8
system abdomen
8
maximum signal
8
healthy subjects
8
subjects patients
8
patients cirrhosis
8

Similar Publications

This study aimed to investigate the potential hypoglycemic mechanism of red ginseng acidic polysaccharides (RGAP) from the perspective of fatty acid (FA) regulation. A high-glucose/high-fat diet in conjunction with streptozotocin administration was employed to establish type 2 diabetes mellitus (T2DM) rat models, and their fecal FAs were detected using the liquid chromatography-mass spectrometry (LC-MS) method. RGAP treatment alleviated the polyphagia, polydipsia, weight loss, and hyperglycemia observed in T2DM rats.

View Article and Find Full Text PDF

The fluorescent imaging of pathologically accumulated β-amyloid (Aβ) proteins is of significant importance to the diagnosis of Alzheimer's disease (AD). In the paper, we prepared two new NIR probes, NIR-1 and NIR-2, through hydrophilic modification of introducing water-soluble bioactive groups such as polyethylene glycol (PEG) and morpholine to tune in vivo pharmacokinetics for specific detection of soluble and insoluble Aβ species. The in vitro assessments confirm that both NIR-1 and NIR-2 display strong near-infrared (NIR) fluorescence (FL) enhancement upon association with Aβ42 monomers, oligomers or aggregates (λem > 670 nm) and show high sensitive, rapid and selective response towards Aβ42 species.

View Article and Find Full Text PDF

Designing Fluorescent Interfaces at Hotspots in a Plasmonic Nanopore for Homologous Optoelectronic Sensing.

Small

January 2025

Department of Chemistry and the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, 361005, P. R. China.

In this work, a site-selective functionalization strategy is proposed for modifying fluorescent dyes in the plasmonic nanopore, which highlights building optoelectronic dual-signal sensing interfaces at "hotspots" locations to construct multiparameter detection nanosensor. Finite-difference time-domain (FDTD) simulations confirmed the high-intensity electromagnetic field due to plasmonic nanostructure. It is demonstrated that adjusting the distance between the nanopore inner wall and fluorophore prevented the fluorescence quenching, resulting in more than a thirty fold fluorescence enhancement.

View Article and Find Full Text PDF

Purpose: Redox homeostasis plays a key role in regulating the overall health and development of organisms. This study aimed to develop a compact and mobile continuous-wave (CW) electron paramagnetic resonance (EPR) imager to facilitate stable, highly sensitive fast three-dimensional (3D) whole-body imaging of nitroxide-infused mice.

Methods: A multiturn loop gap resonator with a diameter of 30 mm and length of 35 mm was designed for whole-body EPR imaging.

View Article and Find Full Text PDF

Key Message:

Abstract: Tree-rings are the prime archive for high-resolution climate information over the past two millennia. However, the accuracy of annually resolved reconstructions from tree-rings can be constrained by what is known as climate signal age effects (CSAE), encompassing changes in the sensitivity of tree growth to climate over their lifespans. Here, we evaluate CSAE in from an upper tree line site in the Spanish central Pyrenees, Lake Gerber, which became a key location for reconstructing western Mediterranean summer temperatures at annual resolution.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!