DNA analysis of fingernail debris using different multiplex systems: a case report.

Int J Legal Med

Institute for Forensic Medicine, University Erlangen-Nürnberg, Universitätsstrasse 22, 91054 Erlangen, Germany.

Published: September 2001

A 55-year-old male nurse was accused of having introduced his fingers by force into the anus of a 20-year-old female patient. Debris from the fingernails of the suspect recovered 2 days after the incident was analysed with the VNTR locus D1S80, the triplex PCR system AmpFlSTR Blue kit, the AmpFlSTR Profiler kit and the pentaplex system genRES MPX. The D1S80 singleplex reaction revealed indications of DNA from the victim in the fingernail debris of the left hand. Using the AmpFlSTR Blue kit and AmpFlSTR Profiler, DNA alleles of the victim were found at four additional loci, while allelic drop-out was observed at five other loci. Only the pentaplex kit genRES MPX revealed alleles at all loci which could be assigned to the victim. Calculation of likelihood ratios resulted in a value of 1.4 x 10(5) using the combination of the multiplex systems AmpF1STR Blue kit and AmpFlSTR Profiler and 2.8 x 10(8) for the genRES MPX kit. This case demonstrates the high sensitivity of the new genRES MPX kit and that DNA profiling of fingernail debris is possible despite a time lapse of 2 days between the incident and recovery of the evidential material.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s004140000187DOI Listing

Publication Analysis

Top Keywords

genres mpx
16
fingernail debris
12
blue kit
12
kit ampflstr
12
ampflstr profiler
12
multiplex systems
8
days incident
8
ampflstr blue
8
mpx kit
8
kit
7

Similar Publications

STR investigations of telogen hair are invariably difficult due to the small amounts of nuclear DNA and its degradation products. However, in recent years there has been a considerable improvement. This study examined the suitability of a new STR kit with shortened amplicons for the investigation of hair in routine casework.

View Article and Find Full Text PDF

The Achilles tendon as a DNA source for STR typing of highly decayed corpses.

Forensic Sci Int

December 2007

Institute of Legal Medicine and Traffic Medicine, University of Heidelberg, 69115 Heidelberg, Germany.

Forensic criminal casework often involves DNA profiling of human postmortem tissues, whereas degradational processes can affect PCR-based Short Tandem Repeat (STR) analysis. Degradation of DNA is observed to vary among different tissues and with time. Therefore, the stability of DNA in Achilles tendon samples is compared to that in muscle and kidney specimens with a variety of postmortem histories.

View Article and Find Full Text PDF

Comparative investigation of hair with the genRES(®) MPX-SP1, genRES MPX-SP2, and genRES MPX-2 kits.

Forensic Sci Med Pathol

March 2007

Institute of Legal Medicine, Ludwig-Maximilians-University of Munich, Frauenlobstrasse 7a, 80337, München, Germany,

In recent years there has been considerable improvement in short-tandem repeat (STR) investigations of hair, which were previously marred by small amounts of nuclear DNA and its degradation. This study examined the suitability of two STR kits with shortened amplicons for the investigation of hairs from routine casework. The overall sucess rate was more than 20%.

View Article and Find Full Text PDF

With the PALM MicroBeam system, precise laser microdissection of single cells from cell smears or tissue preparations is possible. Furthermore, this system uses a contact-free and therefore contamination-free laser pressure catapulting technique in which high energy generated by a focused laser pulse catapults single dissected cells into a collecting vessel. In this study, this technique was tested for forensic purposes with smear preparations from postcoital vaginal swabs, sperm swabs, and buccal cell swabs on different types of microscopic slides.

View Article and Find Full Text PDF

Purification of STR-multiplex-amplified microsamples can enhance signal intensity in capillary electrophoresis.

Int J Legal Med

June 2002

Institut für Rechtsmedizin, Universität Erlangen-Nürnberg, Universitätsstrasse 22, 91054 Erlangen, Germany.

In this study, the effect of sample purification on total signal intensities of samples amplified with genRES MPX-2 (nine-locus multiplex) prior to capillary electrophoretic analysis has been investigated. Sample purification with the Qiaquick PCR purification kit led to an increase of the relative fluorescent signal intensity by a factor of 3.8 +/- 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!