Recent findings of increased isoprene emission in the exhaled breath of patients undergoing haemodialysis and experimental evidence of the potential toxic and cancerogenic effects of isoprene hydrocarbon led us to assess how long haemodialysis patients are exposed to how much isoprene after a single haemodialysis session. Patients with end-stage renal failure on regular 4-hour (from 08.00 to 12.00 h) maintenance haemodialysis three times weekly were monitored. The breath isoprene content was analyzed by gas chromatography. Intrapatient evaluations were performed by collecting samples before, during, and immediately after the haemodialysis session, during the following hours, and on the following nondialysis day. The breath isoprene content increased in all patients. Isoprene overproduction showing a biphasic pattern was first detected soon after the dialysis session ended. These data show that haemodialyzed patients seem to be consistently exposed to high endogenous isoprene concentrations. The mechanisms and implications of this endogenous isoprene overproduction need to be elucidated with regard to the mevalonic pathway and in the physiopathological setting of the uraemia-dialysis syndrome.

Download full-text PDF

Source
http://dx.doi.org/10.1159/000045958DOI Listing

Publication Analysis

Top Keywords

breath isoprene
12
isoprene
9
isoprene emission
8
haemodialysis session
8
isoprene content
8
isoprene overproduction
8
endogenous isoprene
8
patients
5
haemodialysis
5
onset time
4

Similar Publications

Study on exhaled volatile organic compounds identifying cognitive fatigue induced by N-back task in healthy young adults.

Ecotoxicol Environ Saf

January 2025

National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China; China CDC Key Laboratory of Environment and Population Health, Beijing 100021, China. Electronic address:

Cognitive fatigue in specific occupations may present a risk to personal safety. The study aimed to explore the characteristic volatile organic compounds (VOCs) in exhaled breath in response to cognitive fatigue, to provide a scientific basis for the non-invasive exhaled breath diagnostic techniques for cognitive fatigue assessing. Thirty healthy young adults were recruited and assigned to complete two 1.

View Article and Find Full Text PDF

Introduction: Pneumoconiosis represents the most prevalent occupational disease in China, with coal workers' pneumoconiosis (CWP) showing the highest incidence. Analysis of volatile organic compounds (VOCs) in the exhaled breath of CWP patients may provide novel insights into its pathogenesis.

Methods: Study data were collected through questionnaires and medical examinations.

View Article and Find Full Text PDF

Rapid gas sensing with high sensitivity and selectivity is pivotal in advanced production, in smart living, and increasingly in medical health applications. This study presents a novel Pt@InNiO nanoflake isoprene sensor that achieves an exceptionally low limit of detection (LOD) at 2 ppb, the lowest reported for isoprene sensors to date. Notably, it exhibits high selectivity and remarkable antihumidity capacity, thus meeting the stringent requirements for lung cancer screening.

View Article and Find Full Text PDF

Diagnosis of Lung Cancer Through Exhaled Breath: A Comprehensive Study.

Mol Diagn Ther

November 2024

Research Institute, Regional Clinical Hospital, No 1 n.a. Prof. S.V. Ochapovsky, 1 May St. 167, Krasnodar, 350086, Russia.

Objectives: Exhaled breath analysis is an attractive lung cancer diagnostic tool. However, various factors that are not related to the disease status, comorbidities, and other diseases must be considered to obtain a reliable diagnostic model.

Methods: Exhaled breath samples from 646 individuals including 273 patients with lung cancer (LC), 90 patients with cancer of other localizations (OC), 150 patients with noncancer lung diseases (NLD), and 133 healthy controls (HC) were analyzed using gas chromatography-mass spectrometry (GC-MS).

View Article and Find Full Text PDF

Detection of hypoglycaemia in type 1 diabetes through breath volatile organic compound profiling using gas chromatography-ion mobility spectrometry.

Diabetes Obes Metab

December 2024

Department of Diabetes, Endocrinology, Nutritional Medicine and Metabolism, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.

Article Synopsis
  • The study investigates how breath volatile organic compounds (VOCs) relate to glycaemic states in people with type 1 diabetes (T1D), aiming to identify VOCs that can serve as non-invasive biomarkers for hypoglycaemia.
  • Ten T1D individuals were placed in a controlled clinical setting to induce hypoglycaemia, while breath samples were collected and analyzed using advanced gas chromatography.
  • Results showed a strong correlation between specific VOCs, like isoprene and acetone, and blood glucose levels, with machine learning models achieving up to 93% accuracy in classifying glycaemic states, highlighting the potential for breath analysis in diabetes management.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!