Within the last few years meshes have become essential for the temporary closure of the abdominal cavity to avoid the development of an intra-abdominal compartment syndrome. The interposition of a mesh as an inlay reduces the intra-abdominal pressure and improves markedly the blood circulation, particularly for the intestines and kidneys. Whereas non-absorbable meshes usually tend to produce fistulas in direct contact to the bowels, the interposition of short-term absorbable meshes result in large incisional hernias in almost all cases. In the following study we investigated the functional and histological consequences of a short-term absorbable mesh (polyglactin 910, Vicryl, loss of 50% of its mechanical stability within 3 weeks) and a long-term absorbable mesh (polylactide, LTS, preserved >50% of its mechanical stability for over 1 year). The mesh-modifications were both tested with the aid of three-dimensional stereography, tensiometry, light- (LM) and transmission electron microscopy (TEM) as well as morphometry after implantation intervals of 3, 7, 14, 21, 45, 90, 135 and 180 days in a standardised rat model. The PG-mesh initially revealed a pronounced inflammatory reaction and a significantly increased formation of connective tissue. The extensive arrangement of connective tissue in the interface mesh/recipient tissues correlated to an increased stiffness of the abdominal wall compared to the sham-group. However, a loss of mechanical stability and an increase of elasticity could be detected after 3 weeks of implantation which may be explained by the rapid absorption of the mesh material. In contrast to PG, the LTS-mesh indicated a decreased but persisting inflammatory reaction in the interface mesh-fibres/recipient tissues and a significantly reduced induction of connective tissue. Although, the formation of scar-tissue was diminished compared to PG the LTS-mesh preserved its mechanical stability after 180 days. The results indicate that the frequent development of incisional hernias with short-term absorbable meshes (PG) might be due to the decreased mechanical stability and dilatation of the newly formed connective tissue after 2-3 weeks. Moreover, extensive scar tissue development may promote adhesion formation. The implantation of the long-term absorbable LTS-mesh seems to be favourable with respect to its long-term mechanical stability and the decreased connective tissue formation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0142-9612(00)00299-4DOI Listing

Publication Analysis

Top Keywords

mechanical stability
24
connective tissue
20
long-term absorbable
12
short-term absorbable
12
absorbable meshes
8
incisional hernias
8
absorbable mesh
8
180 days
8
inflammatory reaction
8
tissue formation
8

Similar Publications

Real-time monitoring of hemodynamics is crucial for diagnosing disorders within implanted vascular grafts and facilitating timely treatment. Integrating vascular grafts with advanced flexible electronics offers a promising approach to developing smart vascular grafts (SVGs) capable of continuous hemodynamic monitoring. However, most existing SVG devices encounter significant challenges in practical applications, particularly regarding biomechanical compatibility and the effective evaluation of vascular status.

View Article and Find Full Text PDF

Photobiomodulation (PBM) is considered an effective and safe therapeutic modality in supporting the treatment of complications from a global pandemic-diabetes. In this study, PBM therapy is investigated to accelerate wound healing in diabetic mice (DM), under the combined biological effects of red light from a red organic light-emitting diode (ROLED) and near-infrared (NIR) light from an NIR conversion film (NCF) with dispersed CuInS/ZnS quantum dots (QDs). The QD concentration and the NCF structure were optimized to maximize the optical properties and mechanical stability.

View Article and Find Full Text PDF

Porous silicon (pSi) has gained substantial attention as a versatile material for various biomedical applications due to its unique structural and functional properties. Initially used as a semiconductor material, pSi has transitioned into a bioactive platform, enabling its use in drug delivery systems, biosensing, tissue engineering scaffolds, and implantable devices. This review explores recent advancements in macrostructural pSi, emphasizing its biocompatibility, biodegradability, high surface area, and tunable properties.

View Article and Find Full Text PDF

Electromechanics of the Molecule-Electrode Interface and Interface-Mediated Effects in Single-Molecule Junctions.

ACS Appl Mater Interfaces

January 2025

State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Innovation Laboratory for Sciences and Technologies of Energy Materials of Fujian Province (IKKEM), Xiamen University, Xiamen 361005, China.

The molecule-electrode interface can regulate both the efficiency and pathways of electron transport through single-molecule junctions (SMJs). The electromechanics of the interface has proven crucial in exposing the underlying mechanisms of electron transmission through SMJs, providing a theoretical base and practical guidance for designing and constructing functional molecular devices. Here we encompass several currently developed methodologies for investigating the electromechanics of molecule-electrode interface and provide an account of their application in elucidating the effects of the molecule-electrode interface on electron transport properties of SMJs.

View Article and Find Full Text PDF

PEDOT/Polypyrrole Core-Sheath Fibers for Use as Conducting Polymer Artificial Muscles.

ACS Appl Mater Interfaces

January 2025

Sensor and Actuator Systems, Department of Physics, Chemistry and Biology (IFM), Linköping University, Linköping SE-581 83, Sweden.

Electropolymerized polypyrrole (PPy) is considered as one of the promising polymers for use in ionic-electroactive or conducting polymer (CP) actuators. Its electromechanical properties surpass those of other prominent CPs such as poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT/PSS) or polyaniline. However, freestanding and linear contracting actuator fibers made solely of electropolymerized PPy are not available yet.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!