Introduction: Peripheral blood pressure measurements play a prominent role in the diagnosis and follow-up of patients with peripheral vascular diseases. Toe pressure of the hallux (TP1) and second toe (TP2) and transcutaneous oxygen pressure (TCPO2) measurements are becoming more important. The ankle/brachial pressure index (ABPI) is known to be a reliable parameter, but the toe pressure and TCPO2 are evaluated less thoroughly. Therefore, we evaluated the reproducibility of TP1, TP2, TCPO2, ABPI, ankle pressure (AP), and brachial pressure (BP).

Patients And Methods: In 54 patients with various stages of peripheral vascular disease, the intraobserver and interobserver reproducibility of BP, AP, ABPI, TP1, TP2, and TCPO2 was investigated by calculating the repeatability coefficient (RC) and the intraclass correlation coefficient (ICC) and by using Bland-Altman plots.

Results: The intraobserver and interobserver reproducibility at 1 day and after 1 week of BP, AP, ABPI, and TP1 was substantial and comparable (ICC range, 0.80-0.99), except for the BP after 1 week. The TP2 and TCPO2 were less reproducible (ICC range, 0.62-0.98). The interobserver RC of BP was 31 mm Hg; of AP, 44 mm Hg; of ABPI, 27%; of TP1, 41 mm Hg; of TP2, 67 mm Hg; and of TCPO2; 30 mm Hg. The difference plot showed that the observer variability was equally distributed across the range of pressure in all measurements.

Conclusion: The BP, AP, ABPI, and TP1 have a substantial intraobserver and interobserver reproducibility, whereas TP2 and TCPO2 show worse reproducibility. Especially when low values (or values around a cutoff value) are measured, the RC should be taken into account, and repetition of the measurement is advocated.

Download full-text PDF

Source
http://dx.doi.org/10.1067/mva.2001.108011DOI Listing

Publication Analysis

Top Keywords

tp2 tcpo2
20
tp1 tp2
12
intraobserver interobserver
12
interobserver reproducibility
12
abpi tp1
12
pressure
9
peripheral blood
8
oxygen pressure
8
pressure measurements
8
peripheral vascular
8

Similar Publications

Introduction: Peripheral blood pressure measurements play a prominent role in the diagnosis and follow-up of patients with peripheral vascular diseases. Toe pressure of the hallux (TP1) and second toe (TP2) and transcutaneous oxygen pressure (TCPO2) measurements are becoming more important. The ankle/brachial pressure index (ABPI) is known to be a reliable parameter, but the toe pressure and TCPO2 are evaluated less thoroughly.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!