A conventional T1-weighted spin-echo (SE) magnetic resonance (MR) imaging sequence was compared with breath-hold and non-breath-hold half- Fourier single-shot fast SE MR sequences with black-blood preparation and high spatial resolution for imaging of various cardiac diseases. The optimized single-shot fast SE sequence provided better or equal image quality in less time. Breath-hold and non-breath-hold single-shot fast SE sequences may replace the conventional T1-weighted SE sequence for first-line cardiac MR imaging.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1148/radiology.219.2.r01ma27545 | DOI Listing |
NMR Biomed
February 2025
MR Methodology, Department for Diagnostic and Interventional Neuroradiology, University of Bern, Bern, Switzerland.
The purpose of this study was to produce metabolite-specific T and concentration maps in a clinically compatible time frame. A multi-TE 2D MR spectroscopic imaging (MRSI) experiment (multi-echo single-shot MRSI [MESS-MRSI]) deployed truncated and partially sampled multi-echo trains from single scans and was combined with simultaneous multiparametric model fitting. It was tested in vivo for the brain in five healthy subjects.
View Article and Find Full Text PDFJ Magn Reson Imaging
January 2025
Department of Radiology, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China.
Background: Bladder injury during cesarean delivery (CD) in pregnant women with severe placenta accreta spectrum (PAS) disorders mostly occurs in the dissection of vesico-uterine space. Placental MRI may help to assess the risk of bladder injury preoperatively.
Purpose: To identify the high-risk MRI signs of bladder injury during CD in women with severe PAS.
Sci Rep
January 2025
Department of Radiology, Renmin Hospital of Wuhan University, No. 238 Jiefang Road, Wuchang District, Wuhan, 430060, China.
Follicle count, a pivotal metric in the adjunct diagnosis of polycystic ovary syndrome (PCOS), is often underestimated when assessed via transvaginal ultrasonography compared to MRI. Nevertheless, the repeatability of follicle counting using traditional MR images is still compromised by motion artifacts or inadequate spatial resolution. In this prospective study involving 22 PCOS patients, we employed periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) and single-shot fast spin-echo (SSFSE) T2-weighted sequences to suppress motion artifacts in high-resolution ovarian MRI.
View Article and Find Full Text PDFSci Rep
January 2025
Los Alamos National Laboratory, Los Alamos, NM, 87544, USA.
Detecting shielded special nuclear material, such as nuclear explosives, is a difficult challenge pursued by non-proliferation, anti-terrorism, and nuclear security programs worldwide. Interrogation with intense fast-neutron pulses is a promising method to characterize concealed nuclear material rapidly but is limited by suitable source availability and proven instrumentation. In this study we have pioneered a demonstration of such an interrogation method using a high-intensity, short-pulse, laser-driven neutron source that offers potential benefits compared to conventional neutron sources.
View Article and Find Full Text PDFWe present a spectroscopic method that employs a single linearly chirped laser pulse (LCLP) generated by external modulation to realize long-distance multi-point gas sensing. Even without frequency-chirping calibration, accurate single-shot spectral measurement is rendered possible by the high linearity of intrapulse chirping (linearity error of ∼10). Utilizing the LCLP's built-in capacity of time-division-multiplexing, high measurement sensitivity is guaranteed by introducing a multichannel intensity noise compensation mechanism.