Objective: Upper airway dryness is a frequent side-effect of nasal continuous positive airway pressure (nCPAP) therapy in obstructive sleep apnoea syndrome (OSA). In this situation, heated humidification is often used. Therefore, the present study aimed to investigate the humidification performance--defined as the maximum achievable humidity in the tube system of the CPAP device--of a heated humidifier (HH) offered as CPAP accessories, as a function of ambient air conditions (humidity and temperature).
Patients And Methods: In 30 patients (22 male, 8 female, mean age 56.4 +/- 11.7 years) with OSA undergoing CPAP treatment, temperature (T) and relative humidity (RH) in the CPAP tube system were measured, with and without the HH Somnowave, until a steady state was achieved. At the same time, ambient T and RH in the examination room were recorded. T and RH were used to calculate the absolute humidity (AH).
Results: The conditions of the examination room during the examination nights were as follows: T = 21.9 +/- 2.8 degrees C (15.2-26.9), RH 46.5 +/- 11.9% (21.7-69.1) and AH 9.2 +/- 3.2 g/m3 (3.7-16.7). The steady state AH without HH was 9.6 +/- 3.0 g/m3 (4.1-15.4), that with HH (humidification performance) 23.2 +/- 2.8 g/m3 (19.1-29.9) (p < 0.001).
Conclusion: Under the ambient conditions of humidity and temperature, commonly found in European bedrooms, the HH demonstrate a high humidification performance. Thus, it would appear that the HH is suitable for the treatment of dry upper airways under nCPAP therapy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1055/s-2001-11878 | DOI Listing |
Integr Environ Assess Manag
January 2025
Department of Environmental Health Engineering, Faculty of Health, Shiraz University of Medical Sciences, Shiraz, Iran.
This study aimed to evaluate the concentrations of sulfur dioxide (SO2) and nitrogen oxides (NOX) around the Qom (a province in Iran) combined cycle power plant in relation to seasonal variations and fuel type from December 2014 to May 2015. Passive sampling was used in three monitoring sites around the power plant to assess noncarcinogenic health risks associated with exposure to SO2 and NOX. Results showed the higher concentrations of NOX and SO2 in winter than in spring.
View Article and Find Full Text PDFInt Arch Occup Environ Health
January 2025
Xining Centre for Disease Control and Prevention, Xining, Qinghai, 810000, China.
Background: The unique characteristics of air pollution in high-altitude regions may significantly influence the transmission and incidence of influenza. However, current research on this phenomenon is limited, and further investigation is urgently needed.
Methods: This study collected influenza outpatient data from Qinghai Province between January 1, 2016, and December 31, 2021.
Eur Heart J Acute Cardiovasc Care
January 2025
Department of Emergency Medicine, The First Affiliated Hospital of Shenzhen University, Shenzhen Second People's Hospital, Shenzhen 518035, Guangdong, China.
Background: We aimed to analyze the yet unclear correlation between air pollutant concentrations (AP) and out-of-hospital cardiac arrest (OHCA) in Shenzhen, China.
Methods: A 5-year time series analysis of all OHCA events reported to the Shenzhen Emergency Center was conducted. Quasi-Poisson regression, controlling for meteorological variables (daily mean relative temperature and humidity) with multivariable fractional polynomial and using Fourier series to adjust for long-term trends and account for periodic patterns, was used to assess the association among particulate matter of 2.
Introduction: Short-term exposure to air pollution may worsen the course of ischemic heart disease (IHD), causing acute and chronic coronary syndromes.
Objectives: This study aimed to assess the risk of hospital admission due to chronic and acute coronary syndromes (ACS) after exposure to various air pollutants in Poland.
Methods: In this time-series study, the risk of hospital admission due to IHD over 3 days from exposure to several air pollutants was evaluated.
Eur J Prev Cardiol
January 2025
Department of Invasive Cardiology, Medical University of Bialystok, Bialystok, Poland.
Aim: Air pollution remains the single largest environmental health risk factor, while atrial fibrillation (AF) is the most prevalent arrhythmia globally. The study aimed to investigate the relationship between short-term exposure to air pollution and acute AF admissions.
Methods: Individual data on AF hospitalization in the years 2011-2020 were collected from the National Health Fund in Poland (ICD-10: I48.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!