Balloon dilation of coarctation of the aorta has been found to be an effective modality for treatment. Recently, in the older child and adult, implantation of endovascular stents has been considered a clinical alternative to dilation alone. Little is known, however, of the effect of implantation of stents on aortic compliance. To investigate this impact of implantation, we studied 18 piglets, divided into experimental and control groups. At median weight of 14 kg, 2 pairs of ultrasonic crystals were implanted on the aortic wall. After 1 week, all animals underwent catheterization. In the experimental group, a 3 cm long balloon expandable stent was implanted in the descending thoracic aorta between the pairs of crystals. Measurements of arterial pressure and dimensions were performed before implantation and immediately thereafter, and at follow-up catheterization. The index of stiffness, beta, and the the elastic modulus of aortic pressure-strain, were calculated as indexes of arterial compliance. The change in compliance during the period of study was not different between groups. At follow-up, no difference was observed between groups in the velocity of the aortic pulse wave, the augmentation index, or the maximum velocity of flow of blood. The stents remained patent and did not affect aortic growth or medial wall thickness. There was no difference between groups in levels of plasma renin activity and serum aldosterone. In this animal model studied over the short term, therefore, implantation of stents does not affect aortic compliance. Further studies are required to elucidate the long term effects of stents on the hemodynamics affecting the aortic wall and local flow dynamics.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1017/s1047951101000075 | DOI Listing |
J Cardiothorac Surg
January 2025
Department of Cardiology, The first Affiliated Hospital of Wannan, Medical College, Wuhu, China.
Background: He's team have recently developed a new Coronary Artery Tree description and Lesion EvaluaTion (CatLet) angiographic scoring system, which is capable of accounting for the variability in coronary anatomy, and risk-stratifying patients with coronary artery disease. Preliminary studies have demonstrated its superiority over the the Synergy between percutaneous coronary intervention with Taxus and Cardiac Surgery (SYNTAX) score with respect to outcome predictions for acute myocardial infarction (AMI) patients. However, there are fewer studies on the prognostic in chronic coronary artery disease(CAD).
View Article and Find Full Text PDFJ Nanobiotechnology
January 2025
Department of Interventional Radiology, Key Laboratory of Interventional Radiology of Henan Province, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450001, China.
Excessive vascularization during tracheal in-stent restenosis (TISR) is a significant but frequently overlooked issue. We developed an anti-inflammatory coupled anti-angiogenic airway stent (PAGL) incorporating anlotinib hydrochloride and silver nanoparticles using advanced electrospinning technology. PAGL exhibited hydrophobic surface properties, exceptional mechanical strength, and appropriate drug-release kinetics.
View Article and Find Full Text PDFEur Radiol Exp
January 2025
Department of Neuroradiology, University hospital RWTH Aachen, Aachen, Germany.
Background: To define optimal parameters for the evaluation of vessel visibility in intracranial stents (ICS) and flow diverters (FD) using photon-counting detector computed tomography angiography (PCD-CTA) with spectral reconstructions.
Methods: We retrospectively analyzed consecutive patients with implanted ICS or FD, who received a PCD-CTA between April 2023 and March 2024. Polyenergetic, virtual monoenergetic, pure lumen, and iodine reconstructions with different keV levels (40, 60, and 80) and reconstruction kernels (body vascular [Bv]48, Bv56, Bv64, Bv72, and Bv76) were evaluated by two radiologists with regions of interests and Likert scales.
Eur J Vasc Endovasc Surg
January 2025
Aortic Center, Hôpital Marie Lannelongue, GHPSJ, Le Plessis-Robinson, France. Electronic address:
Objective: The aim of this study was to perform a comparative pre-clinical evaluation of a new fenestrated endovascular aneurysm repair dedicated stent using perfused 3D printed patient anatomies.
Methods: The test setup included a pulsatile pump set to reproduce human haemodynamics, four 3D printed pararenal aneurysms connected to a bench test, and four corresponding fenestrated grafts (Zenith Fenestrated; Cook, Bloomington, IN, USA). Bridging stents were sized based on analysis of patients computed tomography scans and included either four standard covered stents (BeGraft [BG]; Bentley, Hechingen, Germany) or four similar covered stent grafts mounted on a modified balloon to allow stent implantation and flaring in one step (BeFlared [BF]; Bentley).
J Cardiovasc Surg (Torino)
February 2025
Department of Vascular Surgery, AZ Sint Blasius, Dendermonde, Belgium.
Background: Due to the heterogeneity of literature findings, stent type selection for the endovascular treatment of complex aorto-iliac occlusive disease remains challenging. The BELSTREAM study, a physician-initiated, prospective, multicenter, single-arm study, aims to report the safety and efficacy of the balloon expandable LifeStream Peripheral Stent Graft System (BD, Tempe, Arizona, USA) for the treatment of complex TASC C and D aorto-iliac artery lesions.
Methods: Seventy patients and 133 lesions were included at six Belgian institutions.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!