The aim of this study was to assess the detectability and distinguishability of the cervical spinal cord, the anterior and posterior spinal roots and of the internal anatomy of the cord (distinction of grey and white matter). For this purpose 20 healthy volunteers were examined using a 1.5 T MR unit with 20 mT/m gradient strength and a dedicated circular polarized neck array coil. Three T2* weighted (w). 2D gradient echo sequences, two T2 w. 2D turbo spin echo (TSE) sequences and one T2 w. 2D turbo gradient spin echo (TGSE) sequence were compared. The multiecho 2D fast low angle shot (FLASH) sequence with magnetization transfer saturation pulse (me FLASH+MTS) yielded the best results for liquor/compact bone, liquor/spinal cord and grey/white matter contrast, as found with regions of interest (ROI) analysis. The single echo 2D FLASH sequence was significantly poorer than the two me FLASH+/-MTS sequences. Two-dimensional TGSE as well as 2D TSE with a 256 matrix and with a 512 matrix yielded the poorest results. In the visual analysis the contrast between liquor and compact bone, liquor and cord as well as liquor and roots was best with me FLASH+MTS, whereas grey/white matter distinction was best using me FLASH-MTS. In conclusion, we would therefore recommend the inclusion of an axial T2* w. multiecho 2D spoiled gradient echo sequence with magnetization transfer saturation pulse and gradient motion rephasing in a MR imaging protocol of the cervical spine.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0720-048x(00)00253-9 | DOI Listing |
J Magn Reson Imaging
January 2025
Department of Radiology, The Third Affiliated Hospital of Soochow University, Changzhou, Jiangsu, China.
Background: As ferroptosis is a key factor in renal fibrosis (RF), iron deposition monitoring may help evaluating RF. The capability of quantitative susceptibility mapping (QSM) for detecting iron deposition in RF remains uncertain.
Purpose: To investigate the potential of QSM to detect iron deposition in RF.
J Magn Reson Imaging
January 2025
Department of Radiology, The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine (Shenzhen Traditional Chinese Medicine Hospital), Shenzhen, China.
Background: Multifrequency MR elastography (mMRE) enables noninvasive quantification of renal stiffness in patients with chronic kidney disease (CKD). Manual segmentation of the kidneys on mMRE is time-consuming and prone to increased interobserver variability.
Purpose: To evaluate the performance of mMRE combined with automatic segmentation in assessing CKD severity.
J Phys Chem Lett
January 2025
Soft Matter Biophysics, Institute for Condensed Matter Physics, TU Darmstadt, Hochschulstraße 8, 64289 Darmstadt, Germany.
Glycolipids are known to stabilize biomembrane multilayers through preferential sugar-sugar interactions that act as weak transient membrane cross-links. Here, we use small-angle and quasi-elastic neutron scattering on oligolamellar phospholipid vesicles containing defined glycolipid fractions in order to elucidate the influence of glycolipids on membrane mechanics and dynamics. Small-angle neutron scattering (SANS) reveals that the oligolamellar vesicles (OLVs) obtained by extrusion are polydisperse with regard to the number of lamellae, , which renders the interpretation of the quasi-elastic neutron spin echo (NSE) data nontrivial.
View Article and Find Full Text PDFInt J Gen Med
January 2025
School of Biomedical Engineering & State Key Laboratory of Advanced Medical Materials and Devices, ShanghaiTech University, Shanghai, People's Republic of China.
Purpose: Conventional brain MRI protocols are time-consuming, which can lead to patient discomfort and inefficiency in clinical settings. This study aims to assess the feasibility of using artificial intelligence-assisted compressed sensing (ACS) to reduce brain MRI scan time while maintaining image quality and diagnostic accuracy compared to a conventional imaging protocol.
Patients And Methods: Seventy patients from the department of neurology underwent brain MRI scans using both conventional and ACS protocols, including axial and sagittal T2-weighted fast spin-echo sequences and T2-fluid attenuated inversion recovery (FLAIR) sequence.
Magn Reson Med
January 2025
Department 8.1 - Biomedical Magnetic Resonance, Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany.
Purpose: To develop a low-cost, high-performance, versatile, open-source console for low-field MRI applications that can integrate a multitude of different auxiliary sensors.
Methods: A new MR console was realized with four transmission and eight reception channels. The interface cards for signal transmission and reception are installed in PCI Express slots, allowing console integration in a commercial PC rack.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!