Objective: To determine the failure mode between dentin-adhesive resin-resin composite bonded joint produced with a chevron-notch short-bar (CNSB) and microtensile test methods.
Methods: Forty teeth were randomly selected for microtensile and forty for CNSB specimen fabrication and stored in 0.5% chloramine T at 37 degrees C until respective static load to failure testing at 30 and 180days. Failure modes were categorized by SEM and tested with Fisher's exact test. Within respective mechanical testing methods the probability of failure curve distributions being significantly different were analyzed by the Wald chi-square statistic.
Results: The characteristic fracture toughness at 30- and 180-day storage was 0.82 and 0.87MPam(1/2), while the Weibull Modulus (m) for the failure distributions, was 4.60 and 4.56, respectively. No significant difference was demonstrated in the failure distributions between these groups (p=0.45). The characteristic tensile strength (muTBS(o)) at 30- and 180-day storage was 52.53 and 14.71MPa with an m of 3.04 and 1.56, respectively. Failure distributions for muTBS groups were significantly different (p<0.001). K(IvM) failure modes, regardless of storage time, were within the adhesive joint with 30-day debonds primarily through the top region of the hybrid layer (THL) and after 180-days involving the bottom of the hybrid layer (BHL). The 30-day muTBS group demonstrated a propensity to debond in dentin or resin composite substrates but after 180-days storage debonds again involved the BHL.
Significance: The weak links in the dentin-adhesive resin-resin composite bonded joint may be the interphase regions between the THL and the adhesive resin and the BHL and dentin.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0109-5641(00)00070-1 | DOI Listing |
ACS Nano
January 2025
CAS Key Laboratory of Magnetic Materials and Devices & Zhejiang Province Key Laboratory of Magnetic Materials and Application Technology, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201, P. R. China.
Flexible magnetic sensors, which have advantages such as deformability, vector field sensing, and noncontact detection, are an important branch of flexible electronics and have significant applications in fields such as magnetosensitive electronic skin. Human skin surfaces have complicated deformations, which pose a demand for magnetic sensors that can withstand omnidirectional strain while maintaining stable performance. However, existing flexible magnetic sensor arrays can only withstand stretching along specific directions and are prone to failure under complicated deformations.
View Article and Find Full Text PDFBackground: To compare the effect of minimally invasive and open transforaminal lumbar interbody fusion (TLIF) approaches in fusing the L4-L5 segment and predicting the potential risk of adjacent segment degeneration (ASD).
Methods: A computed tomography scan image was processed and the three-dimensional model of the L1-L5 spine was reconstructed. The minimally invasive and Open TLIF finite element models were constructed.
Aim: The study aim was to investigate the effect of the 2024 Noto Peninsula earthquake on regular psychiatric outpatient check-ups at Kanazawa Medical University Hospital, Japan.
Methods: We retrospectively collected electronic medical records from January 4 to January 17, 2024, and analyzed data from 656 patients. was used to analyze the association between adherence to scheduled visits and related factors, and the association between inability to attend scheduled visits and self-reported earthquake-related reasons among 84 nonadherent patients.
Front Pharmacol
January 2025
Second Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China.
Background: The efficacy of dexmedetomidine (DEX) in treating sepsis-induced myocardial injury (SIMI) remains unclear. In this study, we explored the relationship between DEX use and clinical outcomes of patients with SIMI, focusing on the dosage and treatment duration.
Methods: In this retrospective cohort analysis, we identified patients with SIMI from the Medical Information Mart for Intensive Care IV (MIMIC-IV) database and categorized them into the DEX and non-DEX groups based on intensive care unit treatment.
Sci Rep
January 2025
College of Mining Engineering, Taiyuan University of Technology, Taiyuan, 030024, Shanxi Province, China.
The influence of interface morphology is of great importance on the shear behavior of the cement mortar-coal composite structure (CCCS) widely distributed in underground mines. In the present research, both the macroscopic- and microscopic failure characteristics of the CCCS with variable interface sawtooth angles (i.e.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!