The medical community has no independent source of timely information regarding the performance of pacemaker and ICD pulse generators and leads. Accordingly, the authors established an Internet-based registry of pacemaker and ICD pulse generator and lead failures (www.pacerandicregistry.com). During the first year, they found three previously unreported device problems that were promptly communicated to the participants. Of the failures reported, 11% of ICD and 10% of pacemaker pulse generator failures were heralded by signs other than the expected elective replacement indicator (ERI). Average ICD battery longevity was 4.0 +/- 0.7 years, and average dual chamber pacemaker battery longevity was 6.8 +/- 2.6 years. Disrupted insulation accounted for 54% of pacemaker and 29% of ICD lead failures. Compared to pacemaker pulse generator and lead failure, ICD device failures were more likely to cause severe clinical consequences. In conclusion, an Internet-based registry is feasible and capable of providing timely data regarding the signs, causes, and clinical consequences of pacemaker and ICD failures.

Download full-text PDF

Source
http://dx.doi.org/10.1046/j.1460-9592.2001.00082.xDOI Listing

Publication Analysis

Top Keywords

pacemaker icd
16
pulse generator
16
icd pulse
12
generator lead
12
pacemaker
8
icd
8
internet-based registry
8
lead failures
8
pacemaker pulse
8
battery longevity
8

Similar Publications

Background: We compared long-term clinical outcomes between patients with cardiac sarcoidosis (CS) who received no treatment (NT), steroid treatment (ST), disease-modifying anti-rheumatic drugs (DMARDs), or tumor necrosis factor alpha inhibitors (TNF).

Methods: Patients from SSM healthcare system's data warehouse were identified using ICD codes. Inclusion criteria included at least 6 months of follow-up.

View Article and Find Full Text PDF

Use of Claims to Assess Outcomes and Treatment Effects in the Evolut Low Risk Trial.

Circ Cardiovasc Interv

January 2025

Richard A. and Susan F. Smith Center for Outcomes Research in Cardiology, Division of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA (C.L., A.T., Y.S., J.S., R.W.Y.).

Background: Food and Drug Administration-mandated postmarket studies for transcatheter aortic valve replacement in low-risk populations plan to use passively collected registry data linked to claims for long-term follow-up out to 10 years. Therefore, it is critically important to understand the validity of these claims-based end points. We sought to evaluate the ability of administrative claims with () codes to identify trial-adjudicated end points and reproduce treatment comparisons of aortic valve replacement in the Evolut Low Risk Trial.

View Article and Find Full Text PDF

Cardiac implantable electronic devices (CIEDs), including pacemakers, implantable cardiac defibrillators (ICD), and cardiac resynchronization therapy (CRT) devices, regulate heart rate and rhythm in patients with cardiac conditions. With an aging population, CIED-related complications, especially pacemaker pocket infections, are rising. Risk factors include frailty, older age, and superficial device fixation, while risk mitigation involves larger pocket sizes, submuscular fixation, and absorbable antibacterial envelopes.

View Article and Find Full Text PDF

Background: Because it is unclear whether implantable cardioverter-defibrillators (ICDs) are equally effective in patients of all ages, we investigated the association of age with long-term clinical outcomes of patients who underwent ICD implantation.

Methods And Results: A total of 416 consecutive patients (mean age: 69 years) from 4 tertiary hospitals who underwent ICD implantation or were upgraded from an existing permanent pacemaker between January 2011 and November 2022 were enrolled and divided into 3 groups based on age: <65 years (n=158), 65-74 years (n=138), and ≥75 years (n=120). We compared the incidence of all-cause death and adverse cardiovascular events, including cardiac death, appropriate ICD therapy, and heart failure hospitalization.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!